Trouble shooting 

 
Valve does not close/open:  Power available? 
 

Compressed air available? 

 

Emergency operation in neutral position? 

 

Solenoid defective? 

 

Check voltage! 

 

Check air pressure! 

 
Leak at gate: 

Clean valve seat and gate seal! 

 

Replace gate seal, if damaged! 

 

Correct air pressure? 

 
Leak at body: 

Flanges leaktight? 

 

Replace bonnet seal! 

 

Screws at bonnet tightened? 

 
 

Repairs 

 
Contact VAT for repairs or maintenance. The fabrication No. (F08- . . . . . / . . . . ) marked on the valve body has always to 
be specified. It has to be individually decided whether the work can be performed by the customer or has to be carried out 
by VAT. 
 
All supplies (e. g. compressed air, electrical power) have to be disconnected for removal/installation of the valve from/into 
the system. 
 

 

Even with disconnected supply, loaded springs and/or air cushions in cylinders can be potential hazards. 

 

 

 

Keep fingers and objects away from the valve opening! 

 
Products returned to VAT for repair have to be free of harmful substances such as e.g. toxical, caustic or microbiological 
ones.  For  radioactively  contaminated  products  the  customer  has  to  fill  in  the  VAT  form  «Contamination  and  Radiation 
Report»  and to  send it  with the  product.  The  form  is available  at  VAT.  The  maximum  permissible values  indicated in the 
form must not be exceeded. 
 

Summary of Contents for 08 Series

Page 1: ...h valve in the following way or similar made in Switzerland Fabrication No patented 96 F08 08 Explanation of symbols Read declaration carefully before you start any other action Keep body parts and ob...

Page 2: ...or any other reproduction processes nor may it be manipulated with electronic systems duplicated or distributed without written permission from VAT Offenders are liable to pay damages The original VA...

Page 3: ...3 8 Technical data Pressure range 1 x 10 7 mbar to 1 6 bar abs Differential pressure on the valve gate 1 6 bar in either direction Differential pressure at opening 30 mbar Admissible temperature Valve...

Page 4: ...tion of the valve The stress has to be relieved by suitable means e g bellows sections Due to the design very slim and the mounting possibility installation between two flanges no forces other than th...

Page 5: ...n indicator according to the following diagrams Standard solenoid Solenoid for impulse actuation option MV 2 1 power 2 1 2 1 close open 1 2 power 2 1 1 2 MV MV MV coil of solenoid MV coil of solenoid...

Page 6: ...Turn clockwise To close the valve Turn counter clockwise Attention Remote operation is only possible if the emergency operation slotted screw is turned counter clockwise to its stop To open the valve...

Page 7: ...8 marked on the valve body has always to be specified It has to be individually decided whether the work can be performed by the customer or has to be carried out by VAT All supplies e g compressed ai...

Page 8: ...wdriver 15 Turn piston 12 clockwise by approx 45 and pull it slowly backwards 16 Drop out balls 15 from bore hole in counter plate 3 Attention Pull out piston to max stroke B DN 63 max stroke B 81 5 D...

Page 9: ...om www vatvalve com 222687EC 2003 04 14 9 8 31 Mount snap ring 9 and check whether it is placed properly in groove 32 Attach compressed air connection 7 33 Close valve 34 Perform function and leak tes...

Page 10: ...on Operating and Maintenance Instructions Series 08 DN 63 100 2 4 VAT Vakuumventile AG CH 9469 Haag Switzerland Tel 41 81 771 61 61 Fax 41 81 771 48 30 CH vatvalve com www vatvalve com 222687EC 2003 0...

Page 11: ...been repaired or altered by anyone other than an authorized VAT representative or that has been subject to improper installation or abuse misuse negligence or accident VAT shall not be liable for any...

Reviews: