![VAT 08 Series Installation, Operating And Maintenance Instructions Download Page 4](http://html1.mh-extra.com/html/vat/08-series/08-series_installation-operating-and-maintenance-instructions_3665117004.webp)
Installation, Operating, and Maintenance Instructions
Series 08, DN 63 - 100 (2½" - 4")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
222687EC
2003-04-14
4/8
Admissible forces
Forces from evacuating the system, from the weight of other components, and from baking can lead to deformation of the
valve body and to malfunction of the valve. The stress has to be relieved by suitable means, e.g. bellows sections.
Due to the design (very slim) and the mounting possibility (installation between two flanges) no forces other than the screw
forces at the flanges may affect the valve.
Compressed air connection
Compressed air may only be connected if
- valve has been installed into the vacuum system
- moving parts cannot be touched
Connect compressed air to the connection
(internal thread R
1
/
8
“,
1
/
8
“ NPT for USA)
Compressed air pressure (min. - max. overpressure): 4 - 7 bar / 55 - 95 psig
Use only clean, dry or slightly oiled air!