VAT 08 Series Installation, Operating And Maintenance Instructions Download Page 6

 

 

Installation, Operating, and Maintenance Instructions 

Series 08, DN 63 - 100 (2½" - 4")

 

 

 

 

 
VAT Vakuumventile AG, CH-9469 Haag, Switzerland 
Tel +41 81 771 61 61   Fax +41 81 771 48 30   [email protected]   www.vatvalve.com 

222687EC

 

2003-04-14 

6/8 

 

Emergency operation at power failure 

 
In case of a power failure, the valve can be actuated according to the following instructions, provided that there is 
compressed air available. 
 

Standard solenoid 

 

Solenoid for impulse actuation (option) 

Emergency operation
(slotted screw)

 

 

Emergency operation

(slotted screw)

Coil «open»

Coil «closed»

5

1

3

 

 

To open the valve: 
  Turn clockwise 
 
To close the valve: 
  Turn counter-clockwise 
 

Attention!

 

Remote operation is only possible if the emergency 
operation (slotted screw) is turned counter-clockwise to 
its stop. 

 

To open the valve: 
  Turn slotted screw of solenoid/coil «OPEN» counter-

clockwise to its stop. As soon as valve is open, turn 
slotted screw back to its original position. 

 
To close the valve: 
  Turn slotted screw of solenoid/coil «CLOSED» 

counter-clockwise to its stop. As soon as valve is 
closed, turn slotted screw back to its original position. 

 

Attention!

 

Remote operation is only possible of both emergency 
operations (slotted screws «OPEN» and «CLOSED») 
are turned clockwise to their stop (initial position). 

 
 
 

Compressed air failure 

 
Valve closed:  valve remains closed 
Valve open: 

valve position is undefined 

Summary of Contents for 08 Series

Page 1: ...h valve in the following way or similar made in Switzerland Fabrication No patented 96 F08 08 Explanation of symbols Read declaration carefully before you start any other action Keep body parts and ob...

Page 2: ...or any other reproduction processes nor may it be manipulated with electronic systems duplicated or distributed without written permission from VAT Offenders are liable to pay damages The original VA...

Page 3: ...3 8 Technical data Pressure range 1 x 10 7 mbar to 1 6 bar abs Differential pressure on the valve gate 1 6 bar in either direction Differential pressure at opening 30 mbar Admissible temperature Valve...

Page 4: ...tion of the valve The stress has to be relieved by suitable means e g bellows sections Due to the design very slim and the mounting possibility installation between two flanges no forces other than th...

Page 5: ...n indicator according to the following diagrams Standard solenoid Solenoid for impulse actuation option MV 2 1 power 2 1 2 1 close open 1 2 power 2 1 1 2 MV MV MV coil of solenoid MV coil of solenoid...

Page 6: ...Turn clockwise To close the valve Turn counter clockwise Attention Remote operation is only possible if the emergency operation slotted screw is turned counter clockwise to its stop To open the valve...

Page 7: ...8 marked on the valve body has always to be specified It has to be individually decided whether the work can be performed by the customer or has to be carried out by VAT All supplies e g compressed ai...

Page 8: ...wdriver 15 Turn piston 12 clockwise by approx 45 and pull it slowly backwards 16 Drop out balls 15 from bore hole in counter plate 3 Attention Pull out piston to max stroke B DN 63 max stroke B 81 5 D...

Page 9: ...om www vatvalve com 222687EC 2003 04 14 9 8 31 Mount snap ring 9 and check whether it is placed properly in groove 32 Attach compressed air connection 7 33 Close valve 34 Perform function and leak tes...

Page 10: ...on Operating and Maintenance Instructions Series 08 DN 63 100 2 4 VAT Vakuumventile AG CH 9469 Haag Switzerland Tel 41 81 771 61 61 Fax 41 81 771 48 30 CH vatvalve com www vatvalve com 222687EC 2003 0...

Page 11: ...been repaired or altered by anyone other than an authorized VAT representative or that has been subject to improper installation or abuse misuse negligence or accident VAT shall not be liable for any...

Reviews: