OPERATION AND MAINTENANCE MANUAL
ID MOTORS
PAGE: 30
CODE: CTT52 EDITION: 03 RELEASE: APRIL 2019
Subject to technical changes without prior notice
Fan and pressure gauge
3.7.7
ID series motors are air-cooled using a forced ventilation system that includes an electric fan powered independently from the
motor.
The fan on the ID series motors can be installed in the following positions:
Motor
Circulation
direction
Standard
position
Optional
positions
ID
Impulsive
Top rear
Side rear
IDX
Suction
Axial
--
Table 18:
Fan position
Other setups are possible on request.
The standard versions of these units are powered with single-phase or three-phase alternating current (see motor technical data
sheet for more information). Other ventilation methods can be studied on request.
Radial electric fans incorporate a washable filter to prevent incoming particles from damaging the motor. This filter requires
regular maintenance (see subsequent sections). This type of fan can include, (as an option on request) an anemostatic relay
(pressure gauge) with a set of NC/NA contacts that open/close when the airflow is insufficient.