If the pump is under warranty, do not disassemble it without consulting the manufacturer or their authorised representative. If this is not
done, then the warranty will not be applicable.
Prior to opening the pump, check that:

it is free from internal pressure.

if liquefied gas is being pumped, that all the gas has been vented.

it is cooled in the case where hot liquids are being used.
In the case of large heavy pumps, for example, the V100-2, V120-2, V150-2, V151, V180 and V200 models, adequate hoisting equipment
is necessary to handle these components.
Prior to hoisting or moving them with belts or cables, ensure that the machine surfaces are protected .
Do not use water to clean the pump or its components. Should this be inevitable, dry it accurately and lubricate with oil.

12.1 Removing the cover (04) 

(fig. 7)

Unscrew the nuts (43). Use the two threaded holes on the cover (if present) to facilitate the removal of the cover.

When removing the cover, care should be taken in order to avoid the basket from damaging (31). Should this occur, replace it. Do not use
damaged gaskets or gaskets with a thickness that is different from that of the original gasket.

Slide the cover-idler assembly carefully out of the pump casing. .

Attention:

When the cover has been removed, the idler may fall off the idler pin if it is not held. This could be a potential cause of injury.

If the pump is fitted with a by-pass relief valve (figure 11) on the cover, it will not be necessary to remove it. If, however, the by-pass valve
requires maintenance, loosen the screw (46) and remove it and ensure that the gasket(s) is/are not damaged (32). If the gaskets are
damaged, replace them..

If the pump is fitted with a heating racket on the cover (R2), this component will separate from the pump as soon as the screws
are removed (43)(See fig. 7).
Should this occur, ensure that the gaskets are not damaged.

If the cover-idler assembly does not require maintenance, go to paragraph 4.6.

12.2 Removing the idler (03)

(fig. 7)

Slip the idler from the idler pin (06). The idler bush is fitted in the centre of the idler. Some versions do not have an idler bush and mount
a large diameter pin.

The idler bushes can be composed of various materials. The choice of the material used depends on different factors such as the type of
application intended etc..

Remove the idler bush by means of a bench press. The brush is normally press fitted.

Clean the bush accurately and check the surfaces for wear. Replace the bush if it has external or localised cracks, signs of abrasion, severe
wear, deformation, external or localized blackening, rust, etc.
The tolerances and clearances of the bush depend on the version of pump used and specific application for which it is intended. It is,
therefore, not advisable to replace the bushes with others of similar dimensions or of different material composition with respect to the
original. The pump may be damaged.

Note:

The bushes play an essential role for the correct functioning of the pump. They have been designed and tested to censure perfect

contact between the idler and the idler pin and between the shaft and support.

Do  not  improvise  alternative  solutions  or  adjustments  which  tend  to  alter  the  tolerances  or  chemical  and  mechanical
characteristics.

After removing the bush, the idler bush can be inspected.

Clean it thoroughly and check the state of wear of the surfaces.

In the case of evident traces of excessive wearing or ovalization of the hole, replace the idler.

Insert the new bush using a bench press using a steady movement. For the V180  and V200 versions, heat the idler to 80

°

C and then fit

the bush. Use a lathe to bring the hole up to tolerance indicated.

12.3 Removing the idler pin (06)

(fig. 7)

The idler pin is fixed to the cover. The pin should be removed only if it requires replacement or when replacing the cover. It is not necessary
to remove it to check the state of wear. The working surfaces of the idler bush sticks out completely from the cover.

Remove the idler pin from its seat by means of a press.
If there are any evident signs of wear, the idler pin should be replaced. If the idler pin shows signs of overheating, this usually indicates
that the idler tends to gall. Check the idler bush and idler thoroughly.

12.4 Removing the casing (01)

(fig. 7)

The casing can be removed without dismounting the pump from the basement. It will be sufficient to remove the screws from the suction
and discharge flange. If the pump mounts a jacketed casing or cover, the auxiliary heating (or cooling) liquid pipes should be removed.

Remove the screws (44)

Disengage the casing from the support-flange (09), paying attention not to damage the basket (30). Should this occur, replace it.

The support-flange remains centred with the support.

Clean the casing thoroughly and check the state of wear.
Replace if necessary.

10

Summary of Contents for V-TRM

Page 1: ...Use and maintenance manual of magnetic drive type cycloidal pumps of the GB V V V VT T T TR R R RM M M M series Features the New PWD Magnetic Coupling by CDR Pompe S p A Milano Italy...

Page 2: ...allation use and preventive maintenance of the V series cycloidal type pumps For disassembly and maintenance see the specific manuals of the various versions For special pumps further information my b...

Page 3: ...CTIONING 5 8 INSTALLATION 5 9 STARTING 7 10 OPERATING PROBLEMS 7 10 1 The pump fails to prime 7 10 2 Low capacity 8 10 3 Excessive pump noise 8 10 4 The pump absorb too muvh power 8 10 5 The pump wear...

Page 4: ...uum gauges rubber or plastic items etc or damage caused by misuse or improper handling of the pump by the end user Parts replaced under guarantee become the property of the manufacturer 3 GENERAL INST...

Page 5: ...nternal magnetic nucleus rotor 02 the magnetic field generates the rotation of the rotor without physical contact A glass 151 is positioned between the two nuclei which hermetically seal the liquid pu...

Page 6: ...to be mounted should be perfectly level and at least 50 100 mm wider than the base plate In order to avoid deforming the base plate shims should be added to the anchor bolts if required The anchor bo...

Page 7: ...nsult the Technical Manual and other specific model manuals or consult the Sales Department Check that all of the valves are open The pump must be started with the suction and discharge valves complet...

Page 8: ...y in accordance to the tables or else heat the product Excessive pressure increase the diameter of the delivery line ensure that all of the valves are open and that the tubing is not clogged Do not ex...

Page 9: ...screw turn it anti clockwise in order to unload the spring until the pressure gauge reading starts to fall below the setting ex 8bar At this point the by pass is set and the delivery valve can be open...

Page 10: ...move the idler bush by means of a bench press The brush is normally press fitted Clean the bush accurately and check the surfaces for wear Replace the bush if it has external or localised cracks signs...

Page 11: ...magnetic nucleus 847 1 remove the seeger 932 1 and the spacer 505 withdraw the primary shaft 213 with the relevant bearings 321 1 321 2 13 ASSEMBLY The normal procedure involves the inverse of what is...

Page 12: ...VARISCO POMPE S r l Zona Industriale Nord Terza Strada 9 35129 PADOVA Italy Tel 049 82 94 312 Fax 049 80 76 762 e mail export variscopompe com Web site www variscopompe com Edition 04 Rev 00...

Reviews: