15
12.8 Mounting the bushes
The idler and shaft bushes be mounted using a press. They are perfectly symmetrical and can therefore be mounted in either direction. When
mounting the bushes in their seats, use a continuos movement. For the V 180 and V 200, heat the idler and rear cover to 80 degrees C before
mounting the bushes. Wait until they have cooled completely and use machine tools to bring them to the tolerance indicated by Varisco.
13
STORAGE
If the pump is to be stored for a certain period of time, it is advisable to empty and clean it. If necessary, wash with a suitable solvent. Avoid
using water.
Pour a little oil, fuel oil, or rust preventer into the pump, grease the bearing and turn the pump over a few times. If the pump is to be left out in
the open, close the ports and cover the pump with a waterproof canvas. Take care to leave holes for ventilation to avoid condensation.
14
SPARE PARTS
To order spare parts, specify the following:
- type of pump
- serial number of the pump
- reference number and description of the part as shown in the exploded drawing
15
DISPOSAL
- Do not abandon in the environment
- Metal parts can be recycled as scrap
- Grease and oil must be recovered and stored as prescribed by the relevant legislation for disposal by approved agencies
- Elastomer gaskets must be removed and disposed of in an approved waste disposal unit