VL3600 PROFILE IP
8
CURRENT VERSUS VOLTAGE
taBle 1
provides the luminaire’s current draw at specific voltages. Total luminaire current is calculated with the
lamp on and all motors sequencing.
2
InsTallaTIOn & seTuP
POWER AND DATA CABLING REQUIREMENTS
CONNECTING POWER
This fixture requires standard AC power distribution from 120-240VAC, 50/60 Hz. Current required depends on
the AC supply voltage and product model
NOTE:
The mating True1 IP 65 compatible connector is supplied; however, you will need to purchase or con-
struct a cable appropriate for your application.
Depending on the application, the luminaire’s AC input cable may require a different connector. If required,
install a new connector meeting your requirements using the following wire color code reference:
WARNING:
DO NOT connect to three-phase service in countries with 240V power.
BATTERY
ENABLE
NETWORK 2
NETWORK 1
USB
AC INPUT
DMX/RDM THRU DMX/RDM IN
WIRE*
CONNECTION
Green/yellow
aC ground
Blue
aC neutral
Brown
aC line
* International (Harmonized) standard
AC VOLTAGE AT 60HZ
TOTAL CURRENT
120V
12.66a
180V
8.22a
208V
7.12a
230V
6.32a
240V
6.12a
TAbLE 1. CURRENT VS. VOLTAGE (1000W LED)
CONNECTION
PIN
aC neutral
X
aC line
Y
Ground (earth)
G
X
Y
G
CONNECTION
PIN
Phase 1
X
Phase 2
Y
Ground (earth)
G
For single-phase power from 120-240 volts RMS:
For three-phase power at 208 volts RMS:
WARNING!
It is the responsibility of the user to ad-
equately protect supply source with a correct size and
type circuit breaker and not overload circuits.
WARNING!
It is not recommended to power any
Vari-Lite luminaire from a dimmer - even in ‘NONDIM’
mode. Dimmer and non-dim modules are not suitable
sources of power because their output modifies the AC
wave form. This may work for a short time, but will even-
tually result in power problems, luminaire mis-operation
and/or failure and may void the luminaire’s warranty.