M
ENU
S
YSTEM
: M
ENU
F
UNCTIONS
4
0 2 . 9 6 8 6 . 0 0 0 1 A
21 - De cem be r- 20 07
49
Inv Pan
Invert Pan
Reverses pan action for special focus requirements.
Inv Tilt
Invert Tilt
Reverses tilt action for special focus requirements.
Lamp
Lamp
Accesses lamp power-up options, reset and information (
Config
) or tests
Lamp function (
Test
).
Lamp
Hours
Lamp Hours
Displays total number of lamp operating hours.
Lamp Level
Lamp Power
Level
Displays lamp power levels:
1500W
,
1200W
, or
900W
.
Lamp OFF
Lamp is Off
Configures arc luminaire so that lamp will not strike upon power up.
Lamp ON
Lamp is On
Configures arc luminaire so that lamp will strike upon power up.
Lum ID
Luminaire ID
Displays unique luminaire ID number.
Magenta
Magenta
Specifies magenta parameter for manual control (
Manual
) or testing (
Test
).
Manual
Manual
Accesses options for luminaire mechanism control by entry of data values.
Movement
Movement
Enables or disables pan and tilt movement.
Normal
Zoom Mode
Zoom configuration is in normal mode.
OFF
Off
Turns off a function.
Off Time
Display off time
Shows the automatic shut-off time for the menu display.
OK
Okay
Indicates calibration has completed and no errors have occurred.
OK?
Okay?
Prompt for pressing [Enter] before an action is executed.
ON
On Indefinitely
Sets Menu Display to stay on until programmed otherwise (
Display
) or turns
on a function.
Pan
Pan
Specifies pan function for manual control (
Manual
) or testing (
Test
).
Pan/Tilt
Pan/Tilt
Accesses pan and tilt options for focus swap function, movement enable/dis-
able, manual control and testing.
PASS
Test Pass
Indicates that a test has passed.
Power
Lamp Power
Accesses options to turn lamp on or off.
Power Up
Power Up
Accesses options for lamp power up state.
PROG
Programming
Currently programming the new version of software.
Re Cal
Recalibrate
Recalibrates luminaire.
Reset
Default
Reset Defaults
Resets default system configuration values.
Reset
Hours
Reset Lamp
Hours
Resets lamp hour and strike counters. (For use when new lamp is installed.)
RUN TEST
Run Test
Indicates that a mechanism test is in progress.
Sensor
Sensors
Accesses sensor types for diagnostic testing.
Status
Status/Error
Allows scrolling through error list or displays
OK
if no errors.
Strobe
Strobe
Specifies strobe function for manual control (
Manual
) or testing (
Test
).
STST
Sensor Test
Indicates that a system sensor test is in progress.
Studio
Zoom Mode
Zoom configuration is in quiet mode for studio use.
Swap
Swap
Swaps pan/tilt action for special focus requirements.
Test
Test
Accesses diagnostic tests for internal mechanisms.
Tilt
Tilt
Specifies tilt function for manual control (
Manual
) or testing (
Test
).
Version
Version
Displays current software version date and time (in two pages).
Table 4-2: Menu Function Definitions (Continued)
Display
Definition
Purpose
Summary of Contents for VL3500 Spot Luminaire
Page 1: ......
Page 13: ...FOREWORD 02 9686 0001 A 21 December 2007 xi...
Page 14: ...VARI LITE VL3500 WASH LUMINAIRE USER S MANUAL xii 21 December 2007 02 9686 0001 A...
Page 18: ...VARI LITE VL3500 WASH LUMINAIRE USER S MANUAL xvi 21 December 2007 02 9686 0001 A...
Page 86: ...VARI LITE VL3500 WASH LUMINAIRE USER S MANUAL 68 21 December 2007 02 9686 0001 A Notes...
Page 87: ......