Self-Tests
Running Parameter Tests
The luminaire is capable of running self-tests by using the
Test
menu functions.
When running tests on multiple luminaires, a male termination connector is required at the last
luminaire in the link. Refer to
“Connecting Data and Power” on page 15
for more information
regarding the construction of this connector.
Note:
After 10 seconds of inactivity, the menu display changes to the default state showing the
address.
To connect luminaires for simultaneous testing:
Step
1. At last luminaire, install male termination connector into DATA THRU XLR connector.
Step
2. At master luminaire Menu Display, press [Menu].
Figure 4-2: Testing Setup
WARNING:
Light Beam Projects Intense Heat
Do not illuminate objects within 3.5 m (11.5 feet) of the VL3500™ Wash Luminaire. Objects within
this range can scorch, melt, or ignite from the heat projected by the light beam.
To run tests:
Step
1. Press [Menu].
Step
2. Press [Up] / [Down] arrows until
Test
appears. Press [Enter].
Step
3. Use [Up] / [Down] arrows to select a parameter to test. Refer to
“Menu System Function
Chart” on page 45
for a complete list of test parameters which can be chosen.
Step
4. Press [Enter] to run test.
Step
5. Press [Menu] to stop test at any time.
DATA THRU
ENTER
MENU
AC PWR
DATA IN
~
AC IN
DATA THRU
ENTER
MENU
AC PWR
DATA IN
~
AC IN
DATA THRU
ENTER
MENU
AC PWR
DATA IN
~
AC IN
Termination Connector
Master Luminaire
Luminaire 1
Luminaire 2
Data Thru
Data Thru
Summary of Contents for VL3500 Spot Luminaire
Page 1: ......
Page 13: ...FOREWORD 02 9686 0001 A 21 December 2007 xi...
Page 14: ...VARI LITE VL3500 WASH LUMINAIRE USER S MANUAL xii 21 December 2007 02 9686 0001 A...
Page 18: ...VARI LITE VL3500 WASH LUMINAIRE USER S MANUAL xvi 21 December 2007 02 9686 0001 A...
Page 86: ...VARI LITE VL3500 WASH LUMINAIRE USER S MANUAL 68 21 December 2007 02 9686 0001 A Notes...
Page 87: ......