I
NSTALLATION
: P
OWER
AND
D
ATA
C
ABLING
R
EQUIREMENTS
2
0 2 . 9 6 8 6 . 0 0 0 1 A
21 - De cem be r- 20 07
9
Data Cables
The VL3500™ Wash Luminaire is equipped with two, 5-pin XLR connectors for DATA IN and
DATA THRU (out) applications. DATA IN requires a 5-pin, female XLR connector and DATA
THRU requires a 5-pin, male XLR connector. When purchasing or constructing data cables, it is
important that not only the correct cable type be used, but also quality cable to ensure a reliable
DMX512 system. Your cabling should meet the following USITT DMX specification requirements:
•
Suitable for use with EIA485 (RS485) operation at 250k baud.
•
Characteristic impedance 85-150 ohms, nominally 120 ohms.
•
Low capacitance.
•
Two twisted pairs.
•
Foil and braid shielded.
•
24 AWG minimum gauge for runs up to 1000 feet (300m).
•
22 AWG minimum gauge for runs up to 1640 feet (500m).
Note:
Microphone type cables and other general purpose, two-core audio or signal cables are not
suitable for use with DMX512.
The XLR 5-pin connectors should be wired as follows:
Note:
Refer to the USITT Recommended Practice for DMX512 guide for additional information
regarding DMX512 systems. How to obtain a copy is detailed in
“Additional Documentation” on
page 1
.
Pin/Wire Code to XLR Connectors
Data Thru
Cable Pinout
Male Conn
Pin 1
Foil &
Braided
Shield
Pin 2
1st
conductor
of 1st
twisted
pair
Data (-)
Pin 3
2nd
conductor
of 1st
twisted
pair
Data (+)
Pin 4
1st
conductor
of 2nd
twisted
pair
Data (-)
Pin 5
2nd
conductor
of 2nd
twisted
pair
Data (+)
Data In
Cable Pinout
Female Conn
1
2
3
4
5
1
2
3
4
5
Summary of Contents for VL3500 Spot Luminaire
Page 1: ......
Page 13: ...FOREWORD 02 9686 0001 A 21 December 2007 xi...
Page 14: ...VARI LITE VL3500 WASH LUMINAIRE USER S MANUAL xii 21 December 2007 02 9686 0001 A...
Page 18: ...VARI LITE VL3500 WASH LUMINAIRE USER S MANUAL xvi 21 December 2007 02 9686 0001 A...
Page 86: ...VARI LITE VL3500 WASH LUMINAIRE USER S MANUAL 68 21 December 2007 02 9686 0001 A Notes...
Page 87: ......