Page 1: ...VL3600 PROFILE IP user manual...

Page 2: ...cluding DMX maps software and photometric reports is available for download on our website For more information on installing DMX512 control systems the following publication is available for purchase...

Page 3: ...ble parts Prior to first use carefully inspect fixture to ensure no damage has occurred during shipping Materials used in the manufacturing process can cause strong odors when the product is new These...

Page 4: ...dissipate heat properly and can damage the luminaire Vari Lite LLC cannot be responsible for issues arising from non approved parts and accessories installed on or used with any Vari Lite LLC product...

Page 5: ...munications As tested under this standard FCC 47CFR 15B clA CEI Issued 2009 10 01 Title 47 CFR Part 15 Subpart B Unintentional Radiators Class A Operation of this equipment in a residential area is li...

Page 6: ...ure shipping container or in its original packing box Be sure to clearly indicate the RMA number on all packing lists correspondence and ship ping labels If available please include a copy of your inv...

Page 7: ...all times improving direct view applications on stage or on camera Color quality enhancement control Dedicated color enhancement wheel which include CRI boost filter and a selection of minus green Ex...

Page 8: ...e in countries with 240V power BATTERY ENABLE NETWORK 2 NETWORK 1 USB AC INPUT DMX RDM THRU DMX RDM IN WIRE CONNECTION Green yellow AC ground Blue AC neutral Brown AC line International Harmonized Sta...

Page 9: ...1640 feet 500m NOTE Microphone type cable and other general purpose two core audio or signal cable are not suitable for use with DMX512 Refer to the USITT Recommended Practice for DMX512 guide for add...

Page 10: ...T 2 110 PVC 22 UL2464 105 41 PC226T 3 110 PVC 22 UL2464 Characteristic impedance TERMINATION CONNECTOR A XLR termination connector is required at the last luminaire or far end of the line to prevent s...

Page 11: ...the steel bracket making premature failure possible A steel washer is recommended to spread this load over a larger surface area To keep the bolt in place The recommended Belleville washer maintains t...

Page 12: ...user manual www vari lite com VL3600 PROFILE IP 12...

Page 13: ...quire few er luminaires on a single data link path Consult your console documentation for more information To connect power and data Step 1 Connect data cable from console to first luminaire in chain...

Page 14: ...d stops at home position only if DMX is not present ADDRESSING PROGRAM STARTING ADDRESS The address setting for DMX console controlled systems is entered using the Menu Display The luminaire retains t...

Page 15: ...tive shipping cases should be used when transporting fixtures to reduce the risk of damage For more information please refer to Vari Lite tech nical notice TN 235 Transportation and Shipping Case Requ...

Page 16: ...two fixed color wheels One holds the normal fixed colors and the second the color adjustments CRI Booster 1 4 and 1 2 Minus Green and CTB NOTE Fixed colors can only be changed by an authorized servic...

Page 17: ...and Gobo Wheel 2 offering 7 rotatable indexable gobos plus one open position GOBO SLOT DMX RANGE CENTER OF IMAGE 1 21 41 31 2 42 62 52 3 63 83 73 4 84 104 94 5 105 125 115 6 126 146 136 7 147 167 157...

Page 18: ...21 25 23 61 65 63 101 105 103 5 26 30 28 66 70 68 106 110 108 6 31 35 33 71 75 73 111 115 113 7 36 40 38 76 80 78 116 120 118 GOBO DIAMETER IMAGE AREA DIAMETER GLASS THICKNESS CARRIER REQUIRED 27mm 1...

Page 19: ...covers See Fig below Step 1 If gasket has been removed inspect the groove and remove any residue Place the flat side of the IP sealing gasket inward and the rounded side outward Step 2 Align the gask...

Page 20: ...vers as described on previous page Step 3 Remove the 4 screws and disconnect the DB Plug at A Step 4 On the other side remove the 2 screws at B and remove the gobo color assembly Step 5 Press down on...

Page 21: ...e gobo with the mark on the carrier as shown in F The coated side should face upwards Apply a small amount of silicon RTV to hold the gobo in place Step 8 Ensure the sun gear on the gobo wheel is orie...

Page 22: ...r requires a magnet to calibrate the gobo index rotation Always ensure the carrier in that position has a magnet installed To replace a fixed gobo see below Step 1 Remove power from luminaire Step 2 R...

Page 23: ...carrier aligning the mark on the gobo with the mark on the carrier as shown in D The coated side should face upwards Apply a small amount of silicon RTV to hold the gobo in place Step 7 Insert the fix...

Page 24: ...tion 13 13 magenta 0 0 255 magenta Color Control 0 100 saturation 14 14 CTO Wheel 0 0 255 CTO Color Control 0 100 saturation 15 15 Color adjustment Color Wheel 2 0 0 255 8 bit control of Color adjustm...

Page 25: ...21 41 Gobo 1 leafy Breakup 42 62 Gobo 2 medium Circle 63 83 Gobo 3 square Pile 84 104 Gobo 4 Confusion 105 125 Gobo 5 Dust 126 146 Gobo 6 neurons 147 167 Gobo 7 radial Breakup 168 188 Gobo 8 staples...

Page 26: ...heel 2 0 56 60 Gobo 3 Bricked Out rotate 61 65 Gobo 4 Horzonal slits rotate 66 70 Gobo 5 super alpha rays rotate 71 75 Gobo 6 Honey Comb reverse rotate 76 80 Gobo 7 On the rocks rotate 81 85 Open no G...

Page 27: ...stest twist set gobo timing to 0 181 210 Gobo Twist normal Path slow to Fast For fastest twist set gobo timing to 0 211 255 reserved Values 0 255 8 bit control of VlFX Gobo Wheel 3 see Channel 27 for...

Page 28: ...alues 28 28 Iris 0 0 255 Iris size control 0 200 Iris beam size open to closed 201 255 Iris pulse slow to fast 29 29 Frame 1a 0 0 255 Controls Framing shutter 1a from Open DmX 0 to Full DmX 255 30 30...

Page 29: ...otate with mega stepping 21 255 reserved Values 42 42 Prism 2 Index rotate High Byte 32767 0 65535 16 bit control of prism rotation and index 0 32756 rotate Fast to slow 43 43 low Byte 32757 32780 rot...

Page 30: ...be random sync 116 120 reserved Values 121 125 reserved Values 126 130 reserved Values 131 135 reserved Values 136 140 reserved Values 141 145 reserved Values 146 150 reserved Values 151 155 reserved...

Page 31: ...5 0 5 6 10 11 15 16 20 21 25 26 30 31 85 86 90 91 95 96 100 101 110 111 115 116 120 121 125 126 135 136 140 141 145 146 150 151 155 156 160 161 165 166 170 171 175 176 180 181 185 186 190 191 255 Cont...

Page 32: ...10 2 52 10 4 53 10 6 54 21 11 55 11 56 22 12 57 12 58 13 59 23 13 60 14 61 24 14 62 14 63 15 64 25 15 65 16 66 26 16 67 16 68 17 69 27 17 70 18 71 28 18 72 18 73 19 74 29 19 75 20 76 30 20 77 20 78 21...

Page 33: ...5 75 186 73 75 187 75 188 80 189 74 80 190 85 191 75 85 192 85 193 90 194 76 90 195 95 196 77 95 197 95 198 100 199 78 100 200 110 201 79 110 202 110 203 120 204 80 120 205 120 206 81 130 207 130 208...

Page 34: ...esCrIPTIOn 0x0031 X X Clear_sTaTus_ID 0x0032 X X suB_DeVICe_sTaTus_rePOrT_THresHOlD 0x0033 Category rDm Information X suPPOrTeD_ParameTers 0x0050 X X X ParameTer_DesCrIPTIOn 0x0051 X X Category Produc...

Page 35: ...ve 0x0343 X X Dimmer Curve Description 0x0344 X X X modulation Frequency 0x0347 X X modulation Frequency Description 0x0348 X Category Power lamp settings 0x04xx X X DeVICe_HOurs 0x0400 X X lamP_HOurs...

Page 36: ...me 0x070C X X Dns_DOmaIn_name 0x070D Category Control 0x10xx X X IDenTIFY_DeVICe 0x1000 X X X reseT_DeVICe 0x1001 X X X POWer_sTaTe 0x1010 X X X PerFOrm_selFTesT 0x1020 all Test Pan Tilt encoder X X s...

Page 37: ...ntrol signel select DmX only artneT On O 0x8aaF X X recalibrate Fixture level 0x8aB0 di erent levels all position color etc X X X DmX Fail Hold Blackout GOTO Preset 0x8aB1 X X X artnet universe 0x8aB2...

Page 38: ...parameter settings set luminaire ID DMX change the map view incoming DMX invert pan tilt Fixture fixture status recalibrate reboot software version view fixtures hours service etc Test test functions...

Page 39: ...de Fan Mode 900Hz 910Hz 920Hz 930Hz 940Hz 950Hz 960Hz 980Hz 990Hz 1000Hz 1500Hz 2500Hz 3000Hz 3500Hz 4000Hz 4500Hz 5000Hz 5500Hz 6000Hz 6500Hz 7000Hz 7500Hz 8000Hz 8500Hz 9000Hz 10KHz 10 5KHz 11KHz 11...

Page 40: ...Reset Defaults DMX 001 to 459 or 464 Address 16 bit Enhanced 16 bit DMX Mode Data Ch 1 Intensity XXX value Ch 2 Intensity Fine XXX value All functions Pan Tilt Swap Pan Tilt Off On Invert Pan Off On O...

Page 41: ...sure Update OS PowerFan 1 xxxx rpm PowerFan 2 xxxx rpm PowerFan 3 xxxx rpm PowerFan 4 xxxx rpm H SinkFan1 xxxx rpm H SinkFan2 xxxx rpm H SinkFan3 xxxx rpm H SinkFan4 xxxx rpm LEDFan1 xxxx rpm LEDFan2...

Page 42: ...lays Pan M_Encoder Encoder Pan xxxxxxx Displays Tilt B_Encoder xxxxxxx Displays Tilt M_Encoder Encoder Tilt Manual Preset 1 to 20 Power Up Preset Playback 0 255 Preset Intensity Preset DMX Priority Pr...

Page 43: ...Menu system consists of several categories Use the Menu Button to access the menu Then use the Up Down arrow to navigate When you reach the desired item touch the Enter But ton To go backwards touch...

Page 44: ...ATTERY ENABLE NETWORK 2 NETWORK 1 USB AC INPUT DMX RDM THRU DMX RDM IN STATUS BAR The Status Bar is always present and displays luminaire operational information of the luminaire The Sta tus Bar conta...

Page 45: ...ure Whisper mode decrease the fan noise further In both Studio mode and Whisper mode the LED output will decrease accordingly Can also be set via the control channel and RDM Fan Mode Fan On runs fans...

Page 46: ...t fo cus on your image If you then adjust the focus channel it will jump to that position based on the DMX value Disabled will cause the lenses to always move based on the DMX values FOLLOW SPOT MODE...

Page 47: ...ed by others WIRELESS DMX VL3600 Profile IP comes with a built in Wireless DMX receiver It supports Lumenradio CRMX format Follow their instructions to configure the transmitter and prepare for pairin...

Page 48: ...ixture Can be performed via the control channel or RDM VERSION Shows the current software version of the fixture Version is listed in MM DD YY format Can be viewed via RDM FIXTURE HOURS Shows the accu...

Page 49: ...and touch ENTER Soft ware will install Diagnostics Fan Check Displays all fan speeds in RPM LED Temp Displays the current and maximum temperature since the last power cycle of the LED engine in C TES...

Page 50: ...he list you wish to edit and touch ENTER Use the UP DOWN buttons to set desired value Touch ENTER to store Then continue to adjust all function desired Movement Shape allows you to select from 3 prese...

Page 51: ...mize light output Cleaning frequency de pends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s opti...

Page 52: ...functions Refer to DMX map and User Interface menu tree to see if your product has one or more of these functions Output Modes These modes are selectable at the fixture s DMX control channel or via t...

Page 53: ...user manual www vari lite com VL3600 PROFILE IP 53 This page intentionally blank...

Page 54: ...nment service signify com NORTH AMERICA SUPPORT entertainment service signify com EUROPEAN CUSTOMER SERVICE CENTER Call 31 0 543 542 531 entertainment europe signify com Call 877 VARI LITE 877 827 458...