background image

Set the DMX address. (FIG 4) 

1. Choose MENU.

2. Use UP/DOWN buttons until D001 is displayed.

3.  Choose ENTER

4. Use UP/DOWN to select the desired start address.

5.   Choose ENTER.

6. DMX start address is now set.

Set Initial Air/Water Ratio (FIG 5) 

1. Set AIR to 7.

2. Set WATER to 2.

3. NOTE: We have found this to be the ratio that works best 

to create a full e

ect plume with little or no water 

collecting on the surrounding area.  

Connect air/water supply (FIG 6) 

1. Prime the Water supply hose by allowing water to 

flow freely thus bleeding the air from the water line.  

2. Align the notch on the air/water connector of the 

supplied adaptor to the notch on the air/water 
connector of the 6b.

3. Firmly seat the connectors until they click, and lock 

into place.

4. Air supplied to the unit should be dry and free from air 

compressor condensation.

5. NOTE: 

Do not cross the streams! 

Air and water 

supply must not be reversed, this may cause 
irreparable damage to the 6b unit.

6. NOTE: The supplied air should be set to 50psi. 

(50-70psi is acceptable).

7. NOTE: The supplied water should be a nominal sink 

tap pressure, free from debris, and can be any potable water. Water line should 
have a fine mesh filter to keep debris out of the  6b.

Power the lighting fixture 

1. Power the lighting fixture per console manufacturer’s instructions.

2. NOTE:  the 6b should be attached to an outdoor rated LED fixture. Conventional 

lighting fixtures may heat up and damage the hoses.  

Page   of 

8

12

Rev. 2.0 11/20

Keypad Label

Scale: Actual Size

2

Menu Enter

Up

Down

63mm

[63.00]

45.2mm

[45.20]

FIG. 4

FIG. 8

Summary of Contents for VF6b

Page 1: ...VF6b Manual Page of 1 12 Rev 2 0 11 20...

Page 2: ...h 6b unit to the light source FIGS 1 2 7 Connect Power and Data to the 6b FIG 3 7 Set the DMX address FIG 4 8 Set Initial Air Water Ratio FIG 5 8 Connect air water supply FIG 6 8 Power the lighting fi...

Page 3: ...dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch The VaporFlame 6b requires an input voltage of 100 240 VAC and has an internal auto switching power supply B...

Page 4: ...ventilation DO NOT place objects directly in the main e ect plume as they may get wet The main plume is described as the part of the e ect closest to the nozzle tip where the water has yet to atomize...

Page 5: ...Page of 5 12 Rev 2 0 11 20...

Page 6: ...mounted at any angle No heat or flammable material makes the VaporFlame safe to use in close proximity to artists gear and scenic pieces The VF6b takes 2 channels of DMX for individual control of the...

Page 7: ...he face of your lighting unit using appropriate screws FIG 2 2 Attach the VaporFlame chassis to the Mounting Adapter using pan head screws and safety nuts 3 NOTE VaporFlame Mounting Adapter will only...

Page 8: ...6b 3 Firmly seat the connectors until they click and lock into place 4 Air supplied to the unit should be dry and free from air compressor condensation 5 NOTE Do not cross the streams Air and water s...

Page 9: ...er thicker e ect but could cause water to collect on surrounding area 6 NOTE Due to di erences in relative humidity the e ect may need to be adjusted for more or less water Nozzles FIG 8 1 Nozzle tips...

Page 10: ...ilding pressure as is supplied to a sink or faucet is fine Unpleasant odors can occur if water is left in the unit for extended periods of time IMMEDIATELY clean the unit if found odors are present We...

Page 11: ...ship back to owner at VaporFlame s expense If VaporFlame determines the fixture is not under warranty VaporFlame will ship the fixture back to the owner at the owners expense If VaporFlame determines...

Page 12: ...nd water hoses are correctly connected to an air and water supply 4 Pinch your fingers over the nozzle tip sealing the output of air and then release This can equalize internal pressure blockages 5 Re...

Reviews: