MULTI-VIEW LINE DRAWINGS

1

10.5”

2.75”

1 2 3 4

STATUS

LOW VOLTAGE OUTPUT STATION-0-10-PWM-1

PWM

LVOS-0-10-PWM-DIN

0-10: 10VDC@100mA MAX
PWM: 12VDC@100mA MAX

INPUT

120-277VAC

50/60 Hz

RELAY: 120-277 VAC/5A MAX. INCANDESCENT

STATION

BUS

CLASS 2

SERIAL NUMBER

NEUTRA

L

NEUTRA

L

LINE

LINE

GN

D

GN

D

2

3

4

1

2

3

IR

4

SENS

PWM OUTPUTS

0-10 OUTPUTS

10mA

MAX

CONTACT INPUT

OVERRIDE

+12V

+12V

GN

D

GN

D

ON

GN

D

OF

F

GN

D

OUT 

1

GN

D

OUT 

2

OUT 

3

GN

D

GN

D

OUT 

4

GN

D

OUT 

1

GN

D

OUT 

2

OUT 

3

GN

D

GN

D

OUT 

4

GN

D

STATION

BUS

CLASS 2

1 2 3 4

0-10

1 2 3 4

RELAY

1

1 2 3 4

STATUS

LOW VOLTAGE OUTPUT STATION-0-10-PWM-1

PWM

LVOS-0-10-PWM-DIN

0-10: 10VDC@100mA MAX
PWM: 12VDC@100mA MAX

INPUT

120-277VAC

50/60 Hz

RELAY: 120-277 VAC/5A MAX. INCANDESCENT

STATION

BUS

CLASS 2

SERIAL NUMBER

NEUTRAL

NEUTRAL

LINE

LINE

GN

D

GN

D

2

3

4

1

2

3

IR

4

SENS

PWM OUTPUTS

0-10 OUTPUTS

10mA

MAX

CONTACT INPUT

OVERRIDE

+12V

+12V

GN

D

GN

D

ON

GN

D

OF

F

GN

D

OUT 

1

GN

D

OUT 

2

OUT 

3

GN

D

GN

D

OUT 

4

GN

D

OUT 

1

GN

D

OUT 

2

OUT 

3

GN

D

GN

D

OUT 

4

GN

D

STATION

BUS

CLASS 2

1 2 3 4

0-10

1 2 3 4

RELAY

9”

8.5”

2.667”

3.32”

10.34”

8.2”

TOP

FRONT

BOTTOM

SIDE

Vantage warranties its products to be free of 

defects in materials and workmanship for a period 

of five (5) years. There are no obligations or 

liabilities on the part of Vantage for consequential 

damages arising out of, or in connection with, 

the use or performance of this product or other 

indirect damages with respect to loss of property, 

revenue or profit, or cost of removal, installation or 

reinstallation.

Vantage garantit que ses produits sont exempts 

de défauts de matériaux et de fabrication pour une 

période de cinq (5) ans. Vantage ne peut être tenu 

responsable de tout dommage consécutif causé 

par ou lié à l’utilisation ou à la performance de 

ce produit ou tout autre dommage indirect lié à 

la perte de propriété, de revenus, ou de profits, 

ou aux coûts d’enlèvement, d’installation ou de 

réinstallation.

Vantage garantiza que sus productos están libres 

de defectos en materiales y mano de obra por un 

período de cinco (5) años. No existen obligaciones 

ni responsabilidades por parte de Vantage por 

daños consecuentes que se deriven o estén 

relacionados con el uso o el rendimiento de este 

producto u otros daños indirectos con respecto a 

la pérdida de propiedad, renta o ganancias, o al 

costo de extracción, instalación o reinstalación.

WARRANTY INFORMATION

INFORMATIONS RELATIVES À LA GARANTIE

INFORMACIÓN DE LA GARANTÍA

Summary of Contents for LVOS-0-10-PWM-1

Page 1: ...4 PWM low voltage outputs 4 Analog 0 10 low voltage outputs 4 High voltage relays tied to low voltage outputs in Design Center Twelve membrane style actuators and LED status indicators High resolutio...

Page 2: ...ed for an IR receiver and light sensor respectively Override Inputs Yes All ON or All OFF contacts Low voltage Output PWM Low Specification IEC 60929 Annex E Number of Outputs 4 Output Voltage 12V Sou...

Page 3: ...load NOTE Loads 1 8 Low voltage outputs should be limited to 250 feet 76 2 meters for each wire run using a minimum of 18AWG 0 823mm2 gauge wire All low voltage connections use 4 4 inch pound torque...

Page 4: ...the Legrand Architectural Dimming Station Bus wiring specification REMOTE INFRARED RECEIVER OR DRY CONTACT A remote infrared receiver part REMOTEIR may be connected to the LVOS 0 10 PWM DIN dry contac...

Page 5: ...OOT CODE If the application code is corrupted it may not be possible for Design Center to connect to the LVOS PWM station to update If this condition is suspected place the LVOS PWM station into boot...

Page 6: ...re Description Type Copper CU Wire only Temperature Rating 60 C MUST MATCH BREAKER LOAD WIRE GAUGE LV NEG LV POS LINE NEUTRAL BALLAST 1 AC INPUT 1 1 2 3 4 STATUS LOW VOLTAGE OUTPUT STATION 0 10 PWM 1...

Page 7: ...LV NEG LV POS LINE NEUTRAL BALLAST 1 AC INPUT LINE NEUTRAL AC INPUT LINE NEUTRAL AC INPUT LINE NEUTRAL AC INPUT 12awg Stranded Breaker feeds can be shared as long as the max AMP is not exceeded check...

Page 8: ...GND GND ON GND OFF GND OUT 1 GND OUT 2 OUT 3 GND GND OUT 4 GND OUT 1 GND OUT 2 OUT 3 GND GND OUT 4 GND STATION BUS CLASS 2 1 2 3 4 0 10 1 2 3 4 RELAY BREAKER 20 AMP STATION BUS To InFusion Controller...

Page 9: ...4 as needed Notice all high voltage is through the LEFT or RIGHT sides of the enclosure and all low voltage is through the CENTER of the enclosure These connections can be through the TOP and or BOTT...

Page 10: ...crew Torque Max Enclosure AC Input Power Maximum Input Voltage Input Frequency Relay Load Incandescent Max Relay Load General Purpose Max Relay Load Electronic Ballast Max STRIP BACK INSULATION 0 25 6...

Page 11: ...2 1 2 3 4 0 10 1 2 3 4 RELAY 9 8 5 2 667 3 32 10 34 8 2 TOP FRONT BOTTOM SIDE Vantage warranties its products to be free of defects in materials and workmanship for a period of five 5 years There are...

Reviews: