9
1
1
2
3
4
ST
AT
US
LOW VO
LT
AGE OUTPUT ST
AT
ION-0-10-PWM-1
PW
M
LV
OS-0-10-PWM-DI
N
0-10: 10VDC@100mA MA
X
PWM:
12
VDC@100mA MA
X
INPU
T
120-
27
7V
AC
50/60 Hz
RELA
Y:
12
0-
27
7
VA
C/5A MAX. INCANDESCEN
T
ST
AT
IO
N
BU
S
CLASS
2
SERIA
L
NUMBER
NEUTRAL
NEUTRAL
LINE
LINE
GND
GND
2
34
1
2
3
IR
4
SEN
S
PWM OUTPUTS
0-10 OUTPUTS
10m
A
MA
X
CONT
ACT INPU
TO
VERRIDE
+12V
+12V
GND
GND
ON
GND
OFF
GND
OUT 1
GND
OUT 2
OUT 3
GND
GND
OUT 4
GND
OUT 1
GND
OUT 2
OUT 3
GND
GND
OUT 4
GND
ST
AT
IO
N
BU
S
CLASS
2
1
2
3
4
0-10
1
2
3
4
RELA
Y
1
1
2
3
4
ST
AT
US
LOW VO
LT
AGE OUTPUT ST
AT
ION-0-10-PWM-1
PW
M
LV
OS-0-10-PWM-DI
N
0-10: 10VDC@100mA MAX
PWM:
12
VDC@100mA MA
X
INPUT
12
0-
27
7V
AC
50/60 Hz
REL
AY
: 1
20-
27
7
VA
C/5A MAX. INCANDESCEN
T
ST
AT
IO
N
BU
S
CLASS
2
SERIAL
NUMBE
R
NEUTRAL
NEUTRAL
LINE
LINE
GND
GND
2
34
1
2
3 IR
4
SEN
S
PWM OUTPUT
S0
-10 OUTPUT
S
10m
A
MA
X
CONT
ACT INPUT
OVERRID
E
+12V
+12V
GND
GND
ON
GND
OFF
GND
OUT 1
GND
OUT 2
OUT 3
GND
GND
OUT 4
GND
OUT 1
GND
OUT 2
OUT 3
GND
GND
OUT 4
GND
ST
AT
IO
N
BU
S
CLASS
2
1
2
3
4
0-10
1
2
3
4
REL
AY
LV
NEG
-
LV
POS
+
LINE NEUTRAL
BALLAST 1
AC INPUT
LV
NEG
-
LV
POS
+
LINE NEUTRAL
BALLAST 1
AC INPUT
1
2
EXAMPLE 1:
ROMEX WIRE FROM BREAKER PANEL
EXAMPLE 2:
SINGLE WIRES FROM BREAKER PANEL
ST
AT
ION BU
S
LINE
NETURAL
GROUND
HIGH-VOLTAGE
CONTROL
GROUND
LOW-VOLTAGE
WIRING KEY
AUX ENCLOSURE WITH LVOS STATIONS EXAMPLE
LVOS Load Wiring Examples using Vantage auxiliary enclosures; order LVOS-0-10-PWM-P-1 for station only and IAUX-2(4) as
needed. Notice all high voltage is through the LEFT or RIGHT sides of the enclosure and all low voltage is through the CENTER of
the enclosure. These connections can be through the TOP and/or BOTTOM of the enclosure from the respective sides. The example
below is identical to the wiring example on the previous page with the exception of the enclosure. Using Vantage’s IAUX enclosures
allows the system to be expanded to a large number of loads.
POSSIBLE LVOS LOADS IN IAUX-2
•
Low-voltage Output: PWM..............................24 Loads
•
Low-voltage Output: 0-10 VDC.......................24 Loads
•
High-voltage 120-277 VAC Output Relays......24 Loads
•
POSSIBLE LVOS LOADS IN IAUX-4
•
Low-voltage Output: PWM..............................40 Loads
•
Low-voltage Output: 0-10 VDC.......................40 Loads
•
High-voltage 120-277 VAC Output Relays......40 Loads
All high-voltage wire runs
through the left and right sides
of the IAUX enclosure
PWM or 0-10V and other low-voltage wire runs
through the center of the IAUX enclosure
WIRING TERMINATIONS
Connector
Torque
Wire Range
Screws Terminals
4.4 Inch Pounds
12-30 AWG*
Wire
Description
Type
Copper, CU Wire only
Temperature Rating
60° C
* MUST MATCH BREAKER / LOAD WIRE GAUGE
(SEE WIRING TERMINATIONS TABLE ABOVE RIGHT)
EXAMPLE 1
(Left side of IAUX Enclosure)
•
Romex wire for station and load fed into the enclosure
•
Neutrals are connected insdie the enclosure and hot
runs through one of the relay loads
EXAMPLE 2
(Right side of IAUX Enclosure)
•
Romex wire run for station power
•
Load wire run is from single wires (run in conduit) HOT
feed is fed into the enclosure, through one of the relay
loads and back out to the fixture
•
Neutrals/GND are straight to the lighting fixture