Vantage Hearth LVOS-0-10-PWM-1 Installation Manual Download Page 9

9

1

1
2
3
4

ST

AT

US

LOW VO

LT

AGE OUTPUT ST

AT

ION-0-10-PWM-1

PW
M

LV

OS-0-10-PWM-DI

N

0-10: 10VDC@100mA MA

X

PWM: 

12

VDC@100mA MA

X

INPU

T

120-
27

7V

AC

50/60 Hz

RELA

Y:

 12

0-

27

VA

C/5A MAX. INCANDESCEN

T

ST

AT

IO

N

BU

S

CLASS 

2

SERIA

NUMBER

NEUTRAL

NEUTRAL

LINE

LINE

GND

GND

2

34

1

2

3

IR

4

SEN
S

PWM OUTPUTS

0-10 OUTPUTS

10m
A

MA
X

CONT

ACT INPU

TO

VERRIDE

+12V

+12V

GND

GND

ON

GND

OFF

GND

OUT 1

GND

OUT 2

OUT 3

GND

GND

OUT 4

GND

OUT 1

GND

OUT 2

OUT 3

GND

GND

OUT 4

GND

ST

AT

IO

N

BU

S

CLASS 

2

1
2
3
4

0-10

1
2
3
4

RELA

Y

1

1

2

3

4

ST

AT

US

LOW VO

LT

AGE OUTPUT ST

AT

ION-0-10-PWM-1

PW

M

LV

OS-0-10-PWM-DI

N

0-10: 10VDC@100mA MAX

PWM: 

12

VDC@100mA MA

X

INPUT

12

0-

27

7V

AC

50/60 Hz

REL

AY

: 1

20-

27

VA

C/5A MAX. INCANDESCEN

T

ST

AT

IO

N

BU

S

CLASS 

2

SERIAL

 NUMBE

R

NEUTRAL

NEUTRAL

LINE

LINE

GND

GND

2

34

1

2

3 IR

4

SEN

S

PWM OUTPUT

S0

-10 OUTPUT

S

10m

A

MA

X

CONT

ACT INPUT

OVERRID

E

+12V

+12V

GND

GND

ON

GND

OFF

GND

OUT 1

GND

OUT 2

OUT 3

GND

GND

OUT 4

GND

OUT 1

GND

OUT 2

OUT 3

GND

GND

OUT 4

GND

ST

AT

IO

N

BU

S

CLASS 

2

1

2

3

4

0-10

1

2

3

4

REL

AY

LV

 NEG 

-

LV

 POS 

+

LINE NEUTRAL

BALLAST 1

AC INPUT

LV

 NEG 

-

LV

 POS 

+

LINE NEUTRAL

BALLAST 1

AC INPUT

1

2

EXAMPLE 1:

ROMEX WIRE FROM BREAKER PANEL

EXAMPLE 2:

SINGLE WIRES FROM BREAKER PANEL

ST

AT

ION BU

S

LINE

NETURAL

GROUND

HIGH-VOLTAGE

CONTROL

GROUND

LOW-VOLTAGE

WIRING KEY

AUX ENCLOSURE WITH LVOS STATIONS EXAMPLE

LVOS Load Wiring Examples using Vantage auxiliary enclosures; order LVOS-0-10-PWM-P-1 for station only and IAUX-2(4) as 

needed. Notice all high voltage is through the LEFT or RIGHT sides of the enclosure and all low voltage is through the CENTER of 

the enclosure. These connections can be through the TOP and/or BOTTOM of the enclosure from the respective sides. The example 

below is identical to the wiring example on the previous page with the exception of the enclosure. Using Vantage’s IAUX enclosures 

allows the system to be expanded to a large number of loads.

POSSIBLE LVOS LOADS IN IAUX-2

• 

Low-voltage Output: PWM..............................24 Loads

• 

Low-voltage Output: 0-10 VDC.......................24 Loads

• 

High-voltage 120-277 VAC Output Relays......24 Loads

• 

POSSIBLE LVOS LOADS IN IAUX-4

• 

Low-voltage Output: PWM..............................40 Loads

• 

Low-voltage Output: 0-10 VDC.......................40 Loads

• 

High-voltage 120-277 VAC Output Relays......40 Loads

All high-voltage wire runs 

through the left and right sides 

of the IAUX enclosure

PWM or 0-10V and other low-voltage wire runs 

through the center of the IAUX enclosure

WIRING TERMINATIONS

Connector

Torque

Wire Range

Screws Terminals

4.4 Inch Pounds

12-30 AWG*

Wire

Description

Type

Copper, CU Wire only

Temperature Rating

60° C

* MUST MATCH BREAKER / LOAD WIRE GAUGE

(SEE WIRING TERMINATIONS TABLE ABOVE RIGHT)

EXAMPLE 1

 (Left side of IAUX Enclosure)

• 

Romex wire for station and load fed into the enclosure

• 

Neutrals are connected insdie the enclosure and hot 

runs through one of the relay loads

EXAMPLE 2

 (Right side of IAUX Enclosure)

• 

Romex wire run for station power

• 

Load wire run is from single wires (run in conduit) HOT 

feed is fed into the enclosure, through one of the relay 

loads and back out to the fixture

• 

Neutrals/GND are straight to the lighting fixture

Summary of Contents for LVOS-0-10-PWM-1

Page 1: ...4 PWM low voltage outputs 4 Analog 0 10 low voltage outputs 4 High voltage relays tied to low voltage outputs in Design Center Twelve membrane style actuators and LED status indicators High resolutio...

Page 2: ...ed for an IR receiver and light sensor respectively Override Inputs Yes All ON or All OFF contacts Low voltage Output PWM Low Specification IEC 60929 Annex E Number of Outputs 4 Output Voltage 12V Sou...

Page 3: ...load NOTE Loads 1 8 Low voltage outputs should be limited to 250 feet 76 2 meters for each wire run using a minimum of 18AWG 0 823mm2 gauge wire All low voltage connections use 4 4 inch pound torque...

Page 4: ...the Legrand Architectural Dimming Station Bus wiring specification REMOTE INFRARED RECEIVER OR DRY CONTACT A remote infrared receiver part REMOTEIR may be connected to the LVOS 0 10 PWM DIN dry contac...

Page 5: ...OOT CODE If the application code is corrupted it may not be possible for Design Center to connect to the LVOS PWM station to update If this condition is suspected place the LVOS PWM station into boot...

Page 6: ...re Description Type Copper CU Wire only Temperature Rating 60 C MUST MATCH BREAKER LOAD WIRE GAUGE LV NEG LV POS LINE NEUTRAL BALLAST 1 AC INPUT 1 1 2 3 4 STATUS LOW VOLTAGE OUTPUT STATION 0 10 PWM 1...

Page 7: ...LV NEG LV POS LINE NEUTRAL BALLAST 1 AC INPUT LINE NEUTRAL AC INPUT LINE NEUTRAL AC INPUT LINE NEUTRAL AC INPUT 12awg Stranded Breaker feeds can be shared as long as the max AMP is not exceeded check...

Page 8: ...GND GND ON GND OFF GND OUT 1 GND OUT 2 OUT 3 GND GND OUT 4 GND OUT 1 GND OUT 2 OUT 3 GND GND OUT 4 GND STATION BUS CLASS 2 1 2 3 4 0 10 1 2 3 4 RELAY BREAKER 20 AMP STATION BUS To InFusion Controller...

Page 9: ...4 as needed Notice all high voltage is through the LEFT or RIGHT sides of the enclosure and all low voltage is through the CENTER of the enclosure These connections can be through the TOP and or BOTT...

Page 10: ...crew Torque Max Enclosure AC Input Power Maximum Input Voltage Input Frequency Relay Load Incandescent Max Relay Load General Purpose Max Relay Load Electronic Ballast Max STRIP BACK INSULATION 0 25 6...

Page 11: ...2 1 2 3 4 0 10 1 2 3 4 RELAY 9 8 5 2 667 3 32 10 34 8 2 TOP FRONT BOTTOM SIDE Vantage warranties its products to be free of defects in materials and workmanship for a period of five 5 years There are...

Reviews: