INCORPORATED
®
Installation
ITC-Series
Inverter
Page 21
Owner‟s Manual 10/7/05
DC Cable Size
Max. Distance
from Inverter to
Battery in Feet
ITC12-2100W/
ITC24-3600W
(ITC12-3200W)
Terminal Lug
- Amp Part
Number
Terminal Crimping Tool
– Amp Part
Number
250MCM Copper
Conductor
24 (16)
325703
AMP DYNA-CRIMP Head - Part #69099
AMP DYNA-CRIMP Die - Part #46751-2
AMP DYNA-CRIMP Hydraulic Power Units -
Part #69120-1 or 314979-1
4/0 Copper
Conductor
20 (13)
321271
AMP Rota-Crimp Part# 600850 (2/0-4/0)
Fuse
Information
Bussman Part
Number
Vanner Part
Number
ITC12-2100
ITC12-3200
ITC24-3600
SP00172
Bussman ANL300
Bussman ANL500
Bussman ANL300
Bussman ANL300
03645
03646
03645
03645
Fuse Holder
Bussman 4164
03637
DC Wiring Installation
The DC input terminals are located in the rear right side of the unit and accessed from the top. The connections
are 5/16-18 brass studs that require a lugged connection and are to be tightened by a torque wrench. The
positive and negative cables enter the compartment through separate strain reliefs located at the right front of
the unit.
WARNING
Never make electrical connections "live". Make the connections to the inverter first, and the battery, last. Make
certain the ON/OFF control switch on front of inverter is in the OFF position before connecting to the battery.
NOTE
Severe damage to the inverter will result, which is not covered under warranty, if wire fragments or other metal
particles enter the inverter through the DC wiring compartment.
Procedure
Step 1: Turn the inverter OFF and disconnect all AC and DC power to the wiring harness. Make sure power
to the inverter wiring is disconnected. Verify that the inverter is turned OFF (the Inverter ON-OFF
switch is in the OFF position).
Step 2: Select a location for the unit. An ideal installation location has the following characteristics:
Close to the battery without being in the battery compartment (usually within six feet).
Protected from the weather.
Well ventilated.
Step 3: Connect the DC cables to the inverter:
A)
Remove the cover plate on the DC cable compartment exposing the positive and negative threaded
studs.
B)
Remove the two flat washers, split ring washers, and nuts from the threaded studs.