Swift1915Z Aura LED Moving Head Beam Wash Light User Manual Swift1915Z Aura LED Moving Head Beam Wash Light User Manual
170
←→
174
175
←→
179
180
←→
201
202
←→
207
208
←→
229
230
←→
234
235
←→
239
240
←→
244
245
←→
249
250
←→
255
LEE 164-Flame red
Open
Color rotation effect
Clockwise, fast to slow
Stop(this will stop wherever the color is at the time)
Counter-clockwise, slow to fast
Open
Random color
Fast
Medium
Slow
Open
CH14
000
←→
255
Zoom
Zoom, from 10-60
Ⅷ
TROUBLE SHOOTING
Following are a few common problems that may occur during operation. Here are some
suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connection of power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
2. If the DMX LED is on and no response to the channel, check the address settings and
DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB
of the unit or the previous one.
4. Try to use another DMX controller.
5. Check if the DMX cables run near or run alongside to high voltage cables that may
cause damage or interference to DMX interface circuit.
C. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor’s drive IC on the PCB might be out of condition.
Ⅸ
MAINTENANCE AND CLEANING
The cleaning of internal and external optical lenses and/or mirrors must be carried out
periodically to optimize light output. Cleaning frequency depends on the environment in
which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater
accumulation of dirt on the unit’s optics.
� Clean with soft cloth using normal glass cleaning fluid.
� Always dry the parts carefully.
� Clean the external optics at least every 20 days. Clean the internal optics at least every
30/60 days.
The following points have to be considered during the inspection:
1) All screws for installing the devices or parts of the device have to be tightly connected
and must not be corroded.
2) There must not be any deformations on the housing, color lenses, fixations and
installation spots (ceiling, suspension, trussing).
3) Mechanically moved parts must not show any traces of wearing and must not rotate with
unbalances.
4) The electric power supply cables must not show any damage, material fatigue or
sediments.
Further instructions depending on the installation spot and usage have to be adhered by a
23
22