background image

 English 

 Installation Instructions 

 

 

WARNING

 - Before starting to install and work with this device, please read 

the 

Safety Instructions

.  

 

When changing or installing a SPCW120 on the SPC system, ensure that all 

anti-static precautions are adhered to while handling connectors, wires, 

terminals and PCBs.   

 

EC Declaration of Conformity 

Hereby, Vanderbilt International (IRL) Ltd declares that this radio equipment type is in 

compliance with all relevant EU Directives for CE marking.  

  Directive 2014/30/EU (Electromagnetic Compatibility Directive) 

  Directive 2014/35/EU (Low Voltage Directive) 

  Directive 2014/53/EU (Radio Equipment Directive) 

  Directive 2011/65/EU Restriction of the use of certain hazardous substances 

Directive) 

The full text of the EU declaration of conformity is available at 

http://pcd.vanderbiltindustries.com/doc/SPC.

 

 

Product Description 

The SPCW120 transceiver provides a wireless interface for the SPC controller that 

enables wireless devices (for example, magnetic contacts, motion detectors, and 

remote controls) to be enrolled on the system.  
The SPCW120 incorporates the following elements, as shown in Fig.1 and Fig. 2. 

 

Fig. 1: SPCW120 transceiver 

Indication LEDs - activated when signals are received.  

Female SMA connector to attach an external antenna.  

1 x 10 pin connector (on back) 

 

Fig.2: Antenna with Tamper Lead 

Locking nut 

SMA male interface for connection to SPCW120 

Tamper lead 

 

Installing the SPCW120 transceiver and antenna in the 

SPC4xxx/5xxx/6xxx housing 

Fig. 3 

Knockouts for antenna on top of housing 

10 pin connector for SPCW120 

Tamper terminal (T1) 

1.  Disconnect the mains supply. 
2.  Remove the cover and disconnect the battery. 
3.  Locate the circular knockouts at the top of the metallic housing. Choose the 

desired knockout for your antenna and carefully knock out an access area. 

4.  Position the SPCW120 on the PCB in the location shown (Fig.3 item 1) with the 

SMA connector/antenna towards the top of the controller board.  

5.  Firmly but gently press down to secure the SPCW120. 
6.  Unscrew the locking nut from the antenna screw fitting and remove it completely 

from the antenna lead. Retain the serrated washer on the antenna. 

7.  Insert the antenna lead, tamper lead, and screw fitting down into the exposed 

knockout opening and pull the lead through until the antenna is sitting flush on 

top of the housing. 

8.  From within the housing, fit the nut over the antenna lead and tamper lead and 

onto the screw fitting of the antenna. 

9.  Tighten the nut on the screw, securing the antenna onto the housing. 
10.  Screw the SMA male connector into the female connector on the SPCW120 

(Fig.1, item 2). 

11.  Connect the tamper lead (Fig.2, item 3) into the tamper terminal (marked T1 on 

the PCB) on the connector block (Fig.3, item 3). 

12.  Reconnect the battery and close the cover.  
13.  Reconnect the mains supply. 
You are now ready to configure your SPC panel to receive wireless signal from 

nearby devices. 

 

  For further instructions about enrolling and configuring your wireless 

devices with your SPC system, please scan the following QR code. 

 

Installing the external antenna (SPCW101) 

Depending on your installation location, it may be necessary to mount an antenna 

away from the SPC4xxx/5xxx/6xxx housing. 
The SPCW101 antenna comes with a single antenna lead of 2 metres. There is no 

tamper lead with the SPCW101 antenna. The long antenna lead enables you to 

choose a mounting position that will enhance the wireless reception of a SPCW120 

transceiver. The antenna is mounted on an external bracket outside the cabinet 

(Fig.6). 
To connect the SPCW101 to the SPCW120 transceiver, follow the steps in the 

section

 Installing the SPCW120 transceiver and antenna in the 

SPC4xxx/5xxx/6xxx housing

 in this document. Ignore the instructions concerning 

the tamper lead.

 

Technical Data SPCW120 

Radio module 

SPC RF receiver (868-869 MHz) 

Operating current  

Max.10 mA at 12 VDC 

Quiescent current 

Max.10 mA at 12 VDC 

Operating temperature 

-10 ~ +50 °C 

Dimensions (W x H x D) 

Module: 34 x 38 x 20mm, Antenna 140 x 22mm 

Weight 

44g (Module 12g, Antenna 32g) 

Cable length SPCW101 

2m 

Standards SPCW120 

Complies to:  

EN50131-3:2009, EN50131-5-3:2005+A1:2008 

 

 Deutsch 

 Installationsanleitung 

 

 

WARNUNG

 - Lesen Sie vor der Installation und Verwendung dieses Geräts 

die Sicherheitshinweise.  

 

Beim Austauschen oder Installieren eines SPCW120 im SPC-System 

müssen während der Handhabung von Anschlüssen, Drähten, Klemmen und 

Platinen alle Antistatik-Maßnahmen getroffen werden.   

 

EG-Konformitätserklärung 

Hiermit erklärt Vanderbilt International (IRL) Ltd, dass dieser Funkgerätetyp den 

Anforderungen aller relevanten EU-Richtlinien für die CE-Kennzeichnung entspricht.  

  Richtlinie 2014/30/EU (Richtlinie über elektromagnetische Verträglichkeit) 

  Richtlinie 2014/35/EU (Niederspannungsrichtlinie) 

  Richtlinie 2014/53/EU (Richtlinie über Funkanlagen) 

  Richtlinie 2011/65/EU (Richtlinie zur Beschränkung der Verwendung 

bestimmter gefährlicher Stoffe) 

Der vollständige Text der EU-Konformitätserklärung steht unter 

http://pcd.vanderbiltindustries.com/doc/SPC

 zur Verfügung. 

 

Produktbeschreibung 

Der Sender-Empfänger SPCW120 bietet eine drahtlose Schnittstelle für den SPC-

Controller, mit der drahtlose Geräte (z. B. Magnetkontakte, Bewegungsmelder und 

Fernbedienungen) im System angemeldet werden können.  
Der SPCW120 besteht aus folgenden Komponenten, die in Abb. 1 und 2 dargestellt 

sind. 

 

Abb. 1: Sender-Empfänger SPCW120 

Anzeige-LEDs 

 Leuchten, wenn Signale empfangen werden.  

SMA-Anschlussbuchse für eine externe Antenne.  

1 × 10-poliger Anschluss (auf der Rückseite) 

 

Abb. 2: Antenne mit Sabotagekontaktkabel 

Abschlussbuchse 

SMA-Anschlussstecker für Verbindung mit SPCW120 

Sabotagekontaktkabel 

 

Installieren des Sender-Empfängers SPCW120 und der Antenne im 

SPC4xxx/5xxx/6xxx-Gehäuse 

Abb. 3 

Vorgestanzte Öffnungen für Antenne auf Gehäuseoberseite 

10-poliger Anschluss für SPCW120 

Sabotagekontaktanschluss (T1) 

1.  Die Stromversorgung trennen. 
2.  Die Abdeckung entfernen und die Batterie ausstecken. 
3.  Vorgestanzte Öffnungen auf der Oberseite des Blechgehäuses suchen. Die 

gewünschte vorgestanzte Öffnung für die Antenne vorsichtig herausbrechen. 

4.  Den Sender-Empfänger SPCW120 an der dargestellten Position (Abb. 3, 

Element 1) auf die Leiterplatte aufsetzen, so dass der SMA-Anschluss und die 

Antenne zur Oberseite der Controller-Platine zeigen.  

5.  Das Modul vorsichtig nach unten drücken, bis der SPCW120 einrastet. 
6.  Die Abschlussbuchse von der Antennenschraubenhalterung abdrehen und 

vollständig vom Antennendraht entfernen. Die Fächerscheibe der Antenne 

aufbewahren. 

7.  Den Antennendraht, das Sabotagekontaktkabel und die Schraubenhalterung 

durch die herausgebrochene Öffnung führen und den Draht so weit durchziehen, 

bis die Antenne bündig auf der Gehäuseoberfläche sitzt. 

8.  Im Inneren des Gehäuses die Abschlussbuchse über den Antennendraht und 

das Sabotagekontaktkabel auf der Schraubenhalterung der Antenne anbringen. 

9.  Die Mutter auf der Schraube festziehen und somit die Antenne auf dem Gehäuse 

befestigen. 

10.  Den SMA-Stecker in die Anschlussbuchse am SPCW120 schrauben (Abb. 1, 

Element 2). 

11.  Das Sabotagekontaktkabel (Abb. 2, Element 3) mit dem Sabotagekontakt (T1-

Markierung auf der Leiterplatte) am Anschlussblock (Abb. 3, Element 3) 

verbinden. 

12.  Die Batterie wieder anschließen und die Abdeckung schließen.  
13.  Die Stromversorgung wieder herstellen. 
Nun kann die SPC-Zentrale konfiguriert werden, um Funksignale von nahe 

gelegenen Geräten zu empfangen. 

Reviews: