Engineer programming via the browser
17
Users
187
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
User/Panel Rights
Select the required user rights that are to be assigned to this user profile.
User rights
Right
User Profile
Type Default
Description
User Rights - Intruder
Fullset
Limited
Standard
Manager
The FULLSET operation fully sets the alarm system
and provides full protection to a building (opening of
any alarm zones activates the alarm).
On selecting FULLSET, the buzzer sounds and the
keypad display counts down the exit time period. Exit
the building before this time period has expired.
When the exit time period has expired, the system is
set and opening of entry/exit zones starts the entry
timer. If the system is not Unset before the entry timer
expires, the alarm is activated.
Partset A
Standard
Manager
The PARTSET A option provides perimeter protection
to a building while allowing free movement through the
access areas.
Zones that have been classified as EXCLUDE A
remain unprotected in this mode. By default, there is no
exit time; the system sets instantly on selection of this
mode. An exit timer can be applied to this mode by
enabling the Partset A timed variable.
Partset B
Standard
Manager
The PARTSET B option applies protection to all zones
except those that have been classified as EXCLUDE B.
By default there is no exit time; the system sets
instantly on selection of this mode. An exit timer can be
applied to this mode by enabling the Partset B timed
variable.
Forceset
Standard
Manager
The FORCESET option is presented on the keypad
display when an attempt is made to set the system
while an alarm zone is faulty or still open (the top line of
the display shows the open zone).
Selecting this option sets the alarm and inhibits the
zone for that set period.
Unset
Limited
Standard
Manager
The UNSET operation unsets the alarm. This menu
option is only presented on the keypad after an
Entry/Exit zone has been activated and a valid user
code has been entered.
Delay Auto Set Standard*
Manager
User can delay or cancel autosetting..
Bypass Delay Standard
Manager
User can automatically override the Unset Delay. Only
available for Financial installations. See
Restore
Standard
Manager
The RESTORE operation restores an alert condition on
the system and clears the alert message associated
with that alert condition.
An alert condition can only be cleared after the zone(s)
or fault(s) that triggered the alert condition have been
restored to their normal operating state and the CLEAR
ALERT option in user programming is selected for that
zone.
Inhibit
Standard
Manager
Inhibiting a zone deactivates that zone for one alarm
set period.
This is the preferred method of deactivating a faulty or
open zone as the fault or open condition is displayed