Engineer programming via the browser
17
Configuring Communications
277
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
NOTICE
For an EN50136-1 ATS, the ATS set up sequence starts with configuring an ATP
for an ATS. This provides you with a quick set up feature. See Quick Start ATP
Configuration for EN50136 ATS [➙ 274].
1. To configure an ATS, go to Communications - FlexC - FlexC ATS.
2. Choose from one of the following options:
Add Single Path ATS
Add Dual Path ATS
Add Dual Path Dual Server ATS
Add Custom ATS.
1. For an EN50136 ATS, you must configure the settings on the ATP
Configuration - EN50136 screen first. See Quick Start ATP Configuration for
2. The ATS Configuration screen displays. An EN50136-1 ATS will display a
primary or primary and backup ATP in the Event Sequence Table.
1. Enter an ATS Name to identify the ATS. If you do not enter a value, the ATS
name defaults to ATS 1, ATS 2 etc.
2. To add 1 primary and up to 9 backup ATPs to an ATS, click Add ATP to FlexC
RCT, see Add ATP to FlexC RCT [➙ 278] or click Add ATP to Analog ARC,
see Add ATP to Analog ARC [➙ 282].
3. Select an Event Profile from the dropdown menu. To customise how events are
transmitted on an ATS, see Configuring Event Profiles [➙ 286].
4. Select a Command Profile from the dropdown menu. To customise the
commands enabled for an RCT to control a panel, see Configuring Command
5. Complete the ATS Faults fields as shown in the table below.
6. Click the Edit Installation Details button to complete the settings to identify the
panel to the RCT operator. See Edit Installation Details [➙ 284].