background image

 

 

Instruction 

 

 

en

en

 

 

 

 

 

 

 

 

 

 

 

ADM-I12W1 motion detector

 

The  detector  detects  movement  in  the 
room  under  surveillance 

 and  initiates 

an  alarm.  It  responds  most  sensitively  to 
movement  in  the  directions  indicated  by 
arrows 

B  /  D

.  The  alarm  is  transferred 

by wireless. The back tamper recognizes 
if the detector is removed with force.

 

 

Prerequisites 

The detector should be installed by peo-
ple with specialist knowledge and in com-
pliance with valid regulations.  

 

 

The  detector  is  only  intended 
for  indoor  use.  Note  the  posi-
tioning instructions 

 

 

Opening the detector 

1. Check the scope of delivery

2. Slide up the screw-on cover 

A

 and 

loosen the screw 

B

3. Pull the housing front 

D

 off the base 

C

 

Fitting the detector 

1. Fit the mounting base 

C

 as follows: 

-  Define type of fastening 

A / B

. (also 

refer to mounting bracket option) 

-  Break open three fixing holes. 
-  Fit mounting base at the proposed 

height. 

 

 

The mounting base should be 
secured  using  two  screws 

A   /  B

  and  the  back  tamper 

with one screw 

C

 

2. Pull out insulation strip between bat-

tery and bracket 

A

 

3. Press the tamper contact 

B

 to regis-

ter the detector with the system. 

 

 

For  safety  reasons  only  use 
the  battery  supplied  and  not 
any other type. 

 

4. Fold front 

D

 back onto mounting 

base 

C

 and secure with screw 

B

Slide down screw-on cover 

A

 

Programming 

To adjust the settings to the application, 
move the switches 

A

 into the corre-

sponding positions: 
 

Switch  Function 

ON 

OFF 

LED 

*On 

Off 

Sensitivity 

*Low 

High 

Auto Power Save 

*On 

Off 

Pet Immunity 

25kg  *15kg 

* Factory Setting 
 
 

Sensitivity setting 

D

 

 

Turn potentiometer 

D

 

into the position required to 
adjust detector to room size 
and field of vision. 

*

 

factory setting is the middle position 
(12-meter field of vision) 

    Potentiometer settings other than the 

centre (factory) position are not certi-
fied by Telefication for EN compliance 
and will result in a different coverage 
area.

 

 

ID registration 

You will find instructions for integrating 
the detector in the control panel in the 
control panel's installation manual. 

 

Walk test 

1.  Call up walk test mode in the control 

panel.  

2.  Hold a magnet to the right of the de-

tector for 1 second

 

B.

 

3.  Run the walk test for alarm triggering 

in the whole detection area 

 of the 

detector. 

 

Alarm transmission test 

1.  Call up walk test mode in the control 

panel. 

2. Hold a magnet to the right of the detec-

tor for at least 2 seconds

 

B.

 

3.  The  alarm  transmission  test  has  now 

started. 11 test signals are sent to the 
control  panel  at  an  interval  of  6  sec-
onds  (the  LED 

 

flashes during  each 

transmission).  

4. The test is passed if the control panel 

receives the test signals and indicates 
this accordingly. 

 

Options

 

Narrow angle lens kit AO-C25 

The kit enables the detection area cover-
age  to  be  defined  to  a  narrow  angle  as 
shown in 

D

Loosen the lens currently at the positions 
shown in 

F

 and remove from the detec-

tor. Insert adapter 

C

 in to detector and 

press down narrow angle lens. 

 

White light filter AO-WL10k* 

The white light filter is needed for applica-
tions with extreme white light interference 
(> 4000 lux). 
Loosen the lens currently at position 

F

 

and remove this from the detector. Insert 
adapter 

B

 in to detector and press the 

lens back down. 

Note: Not certified by Telefication for 

EN compliance. 

 
Wall & ceiling mounting brackets

 

 

The  mounting  brackets  AZ-MBG2

A

 

(ceiling 

B

 and wall 

C

 mounting) can 

be used to swivel the detector ±45°. 
 
 

 

Technical data 

Detection area cov-
erage 
wide angle 

B

 

12 m 

Detection area cov-
erage 
narrow angle 

D

 

20 m 

Range of wireless 
module 

Up to 300 m out-

doors 

Frequency: 
ADM-I12W1 

 

868 MHz 

Identification 

ID serial number 

24 bits 

Data protocol 

SiWay 

Event transmission 

Alarm, sabotage, 
surveillance, bat-

tery low 

Test mode 

Walk test & alarm 

transmission test 

Battery power sav-
ing 

Automatic energy 

saving function 

Battery 

Lithium 3 V 

Type: xx123 
Size: 2/3 AA 

Capacity: 1550mAh 

Warm up period 

60 ±5 s 

Pet immunity  

<15 kg 
<25 kg 

EMI rejection up to 
2 GHz 

>10 V/m 

Operating tempera-
ture 

-

10 °C…+50°C 

Storage tempera-
ture 

-

20 °C…+60 °C 

Air humidity 
EN 60721 

<85 %rF, not con-

densing 

Type of housing 
protection 
EN 60529, 
EN 50102 

IP41 / IK02 

 
EC Declaration of Conformity 

Hereby, Vanderbilt International (IRL) Ltd 
declares that this radio equipment type is 
in compliance with all relevant EU Direc-
tives for CE marking. From 20/04/2016 it 
is in compliance with Directive 
2014/30/EU (Electromagnetic Compatibil-
ity Directive) and Directive 2014/35/EU 
(Low Voltage Directive). From 13/06/2016 
it is also in compliance with Directive 
2014/53/EU (Radio Equipment Directive). 
The full text of the EU declaration of con-
formity is available at: 

http://pcd.vanderbiltindus-
tries.com/doc/wireless

 

7

7

6

1

2

2

2

2

2

4

4

4

8

5

2

2

2

2

5

5

5

8

7

8

10

7

5

3

5

3

9

9

9

9

7

7

Summary of Contents for Intrunet E-Line ADM-I12W1

Page 1: ...e movimiento inal mbrico Tr dl s r relsedetektor Radiowy czujnik ruchu Draadloze bewegingsdetector en de fr it es nl STEP Installation manual A5Q00035337_f Edition 04 04 2016 CADIM A5Q00035337 P N 710...

Page 2: ...s la commande Informazioni relative all or dinazione Datos de pedido Best llnings information Informacje po trzebne przy zam wieniu Bestelinformatie ADM I12W1 V54538 F105 A100 PIR Detector 868 MHz PIR...

Page 3: ...up walk test mode in the control panel 2 Hold a magnet to the right of the detec tor for at least 2 seconds B 3 The alarm transmission test has now started 11 test signals are sent to the control pan...

Page 4: ...ttlungstest 1 Rufen Sie in der Zentrale den Gehtest Modus auf 2 Halten Sie mindestens 2 Sekunden lang einen Magneten rechts neben den Melder B 3 Der Alarm bermittelungstest ist jetzt gestartet Es werd...

Page 5: ...r le mode de test de d placement 2 Pendant au moins deux secondes tenir un aimant droite du d tecteur B 3 Le test de transmission d alarme est pr sent lanc 11 signaux de test espa c s de 6 secondes so...

Page 6: ...ttiva del rivelatore Test di trasmissione dell allarme 1 Richiamare la modalit Test di attraversamento nella centrale 2 Tenere un magnete alla destra del rivelatore B per almeno 2 secondi 3 Il test di...

Page 7: ...r Prueba de transmisi n de alarma 1 Llame el modo de prueba de paseo en la unidad de control 2 Sit e durante al menos 2 segundos un im n a la derecha del detector B 3 Ahora est iniciada la prueba de t...

Page 8: ...tsignaler s nds till centralen med intervall p 6 sekunder LED blinkar till vid varje verf ring 4 Testet r godk nt om centralen tar emot och indikerar testsignalerna Tillval Rid linssats AO C25 Med den...

Page 9: ...i na ruch 2 Po prawej stronie czujnika B przytrzyma magnes przynajmniej przez dwie sekundy 3 Rozpocz si test transmisji alarmu W odst pie 6 sekund nast puje przes anie 11 sygna w testowych do centrali...

Page 10: ...detector uit Test alarmoverdracht 1 Roep in de centrale de modus voor de looptest op 2 Houd minstens 2 seconden een magneet rechts naast de detector B 3 De test van de alarmoverdracht is nu gestart Er...

Reviews: