6000 COUNTS DIGITAL MULTIMETER
USER'S MANUAL
4
*
In TV repair work, or when carrying out measurements on power switching circuits, remember that high amplitude
voltage pulses at the test points can damage the multimeter. Use of a TV filter will attenuate any such pulses.
*
Use just one 6F22 battery, properly installed in the Meter's battery case, to power the Meter.
*
Replace the battery as soon as the battery indicator ( ) appears. With a low battery, the Meter might produce false
readings that can lead to electric shock and personal injury.
*
Do not measure voltages above 1000V in Category III, or 600V in Category
Ⅳ
installations.
*
Do not operate the Meter with the case (or part of the case) removed.
1.2 Symbols:
Symbols used in this manual and on the instrument:
Caution:
refer to the instruction manual. Incorrect use may result in damage to the
device or its components.
~
AC (Alternating Current)
DC (Direct Current)
AC or DC
Earth ground
Double insulated
Fuse
Conforms to European Union directives
1.3 Instructions
*
Remove test leads from the Meter before opening the Meter case or battery cover.
*
When servicing the Meter, use only specified replacement parts.
*
Before opening up the instrument, always disconnect from all sources of electric current and make sure you are not
charged with static electricity, which may destroy internal components.