background image

www.vanco1.com

 800-626-6445

14

Default Mode

In this mode, WIFI is enabled as well as the WAN and LAN ports are enabled. The RS232-IP also can work in the AP 

(access point) mode. This setting allows elements from all the modes to be used and set up accordingly, and can even 

act as a wireless/wired Ethernet router.  WIFI device(s) can connect with the RS232-IP, and become one device within 

the associated network.  WAN default IP is dynamic IP address.

Summary of Contents for RS232-IP

Page 1: ...RS 232 and IP Router Vanco Part Number RS232 IP Technical Support www vanco1 com techsupport vanco1 com 800 626 6445 ...

Page 2: ...cularly at the plugs 9 Use unit only with accessories specified by the manufacturer 10 Refer all servicing to qualified personnel CAUTION HDMI is a very complex technology requiring continuous authentication of the signal and the same video resolution and audio settings on all electronic equipment in the system When there are multiple sources and displays the video resolution and audio setting on ...

Page 3: ...etwork RS 232 and IP Router Part RS232 IP LAN Wi Fi to Serial adapter that allows for remote access configuration and the ability to control any serial device over an IP network Enables seamless communication via serial port Ethernet or any wireless network interface Wired Wireless Router and wireless access point capability Converts commands received over UDP or TCP IP to Serial Supports RS232 an...

Page 4: ...k Management Remote Web management Configuration file import and export WEB software upgrade Maximum Transmission Rate 500000bps TCP Connection Max connection number 20 UDP Connection Max connection number 20 Serial Baud Rate 1200 500000bps Status indicator Status indicator Operating Temperature 20 70 Degrees C Operating Humidity 10 90 RH noncondensing Storage Temperature 40 80 Degrees C Storage H...

Page 5: ...800 626 6445 5 PANEL DESCRIPTIONS 1 RS232 DB9 Female 2 Power Supply Input 3 Antenna Screw Terminal 4 Reset RST 5 WAN RJ45 6 LAN RJ45 7 Wifi Status 1 6 7 4 2 5 3 ...

Page 6: ...32 Connection 1 5 6 9 Pinout Number Function Input Output Description 1 N A N A N A 2 RXD Input Data receiving input 3 TXD Output Data sending ouput 4 N A N A N A 5 GND Input Ground 6 N A N A N A 7 N A N A N A 8 N A N A N A ...

Page 7: ...RX Input Receive Data 7 N A N A N A 8 N A N A N A RST Button The RST reset button is used to reset the RS232 IP to factory default settings When the RS232 IP completes startup press and hold the RST button for 10 seconds All of the parameters and settings of the unit will be reset to default 5V Power Input Voltage range 4 5 5 5V The default configuration of RS232 IP for the power adapter is 5V 1A ...

Page 8: ... Default combination of any the above mentioned modes Connect and Operate Ethernet to Serial In this mode LAN is enabled and WIFI WAN functions and ports are closed Through the appropriate settings the data between the computer and the LAN port on the RS232 IP can be achieved through the network through category cables Ethernet can be configured as a dynamic IP address DHCP or can also be configur...

Page 9: ...to the same LAN via an ethernet switch or router 3 Connect a computer either directly to the RS232 IP LAN port or to the network the RS232 IP is connected to and set the network segment to be the same as the RS232 IP s segment 192 168 16 XX Default 192 168 16 254 4 Enter the default IP address of 192 168 16 254 into any web browser to enter the user interface Username admin Password admin ...

Page 10: ...to communicate through the network Once changes are completed select Apply for changes to take effect NOTE After changes have been applied you may need to sign back into the user interface using the new IP information and address 5 Under the NetMode drop down menu select ETH SERIAL ...

Page 11: ...n be achieved through the network WIFI CLIENT can be configured as a dynamic IP address DHCP or can also be configured as a static IP address STATIC 1 Power up the RS232 IP The Link light will blink slowly after powering up 2 Connect a computer either directly to the RS232 IP LAN port or to the network the RS232 IP is going to be associated and set its network segment to be the same as the RS232 I...

Page 12: ...d to sign back into the user interface using the new IP information and address 3 Enter the default IP address of 192 168 16 254 into any web browser to enter the user interface Username admin Password admin 4 Under the NetMode drop down menu select WIFI CLIENT SERIAL ...

Page 13: ...cable and change the settings as needed for the RS232 IP to communicate through the network Once changes are complete select Apply for changes to take effect 5 Select the Scan button This will take you to a page to locate your network by the SSID Once you find and select your correct network click Apply ...

Page 14: ...2 IP also can work in the AP access point mode This setting allows elements from all the modes to be used and set up accordingly and can even act as a wireless wired Ethernet router WIFI device s can connect with the RS232 IP and become one device within the associated network WAN default IP is dynamic IP address ...

Page 15: ...out The time of Serial Framing typically remains unchanged Network Mode Choose Client Server or none Remote Server Domain IP Remote Server Domain IP address Locale Remote Port Number The specified parameter is not the same under the different network modes Client specifies the port number on the remote Server specified local port number Network Protocol Use TCP IP or UDP Protocol Network Timeout U...

Page 16: ...d is sent to TCP Client end TCP Client In this mode the module is connected to a specified domain or IP port All of the data sent from the TCP Server side end will be sent directly to the serial port and the data from the serial end will be sent to the TCP Server side NOTE When the TCP Active reconnection function is enabled and the TCP Server initiative is disconnected the module will immediately...

Page 17: ...e serial port and record the remote IP port The module will only record the last information on the remote connection Received serial data will be sent directly to the recorded remote IP port UDP Client In this mode the module directly sends the serial data to the specified IP port The serial data returned from the server side will be distributed to serial port ...

Page 18: ...gs English Chinese Administrator Settings Change username and password from default System Reboot Restore the RS232 IP to factory default settings SYSTEM MANAGEMENT SETTINGS MANAGEMENT Export Import or load settings saved on a computer ...

Page 19: ... www vanco1 com for the latest firmware 2 Select Open 3 Select Apply NOTE DO NOT TURN OFF THE COMPUTER OR RS232 IP UNTIL THE UPDATE IS COMPLETED When in WIFI AP SERIAL mode allows the user to check the status of the RS232 IP as well as monitor the stations associated with the AP ...

Page 20: ...nstall this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing may expose you to dangerous voltage or other hazards Install the device in a place with fine ventilation to avoid damage caused by overheat Keep the module away from liquids Spillage into the housing may result in fire electric...

Page 21: ...risk of damage to the unit Follow all instructions and warnings marked on this unit Do not attempt to service this unit yourself except where explained in this manual Provide proper ventilation and air circulation and do not use near water Keep objects that might damage the device and assure that the placement of this unit is on a stable surface Use only the power adapter and power cords and conne...

Page 22: ...will be free from defects in materials and workmanship for a period of two years from the date of purchase Should this product in Vanco s opinion prove defective within this warranty period Vanco at its option will repair or replace this product without charge Any defective parts replaced become the property of Vanco This warranty does not apply to those products which have been damaged due to acc...

Page 23: ...nstruction Manual prior to calling or installing this unit since it will familiarize you with the capabilities of this product and its proper installation All active electronic products are 100 inspected and tested to insure highest product quality and trouble free installation and operation The testing process utilizes the types of high definition sources and displays typically installed for ente...

Page 24: ...Vanco International 506 Kingsland Drive Batavia Illinois 60510 call 800 626 6445 fax 630 879 9189 visit www vanco1 com ...

Reviews: