DESCRIPTION Section 2 - Pg 07
2.7 Instrument Panel, Functional Description
Refer to
Figure 2-4
. The instrument panel group consists of a receiver pressure gauge,
an hour meter, a compressor discharge temperature gauge and reset button.
The
air pressure gauge
continually monitors the sump pressure at various load
and\or unload conditions.
The
hour meter
indicates the cumulative hours of compressor operation which is
useful for planning and logging service operations.
The
compressor discharge temperature gauge
monitors the temperature of the
air/fluid mixture leaving the compressor unit. The normal reading should be
approximately 180°F to 210°F.
The
reset button
cancels and/or resets over-pressure/over-temperature shut-down
condition.
WARNING: Never force
the reset button back into position, or hinder it in any
way, in order to allow for machine operation. A tripped reset button indicates a
problem that should be addressed and resolved before operation can continue.
NOTE:
When re-starting the compressor, make sure receiver tank pressure has blown
down to 10 psig can put extra load on the hydraulic system.
AIR PRESSURE
GAUGE
HOUR METER
DISCHARGE
TEMPERATURE
GAUGE
RESET
BUTTON
Figure 2-4: Instrument Panel Group
Summary of Contents for ADHD Powertech
Page 8: ...BLANK PAGE...
Page 16: ...BLANK PAGE...
Page 19: ...DESCRIPTION Section 2 Pg 03 Figure 2 1 Compressor Discharge and Cooling and Lubrication System...
Page 31: ...INSTALLATION Section 5 Pg 03 5 3 Wire Diagram 266551_r1_ TP...
Page 32: ...INSTALLATION Section 5 Pg 04 5 4 Dimensions Diagram 263620_r1_ TP...
Page 40: ...BLANK PAGE...
Page 46: ...PARTS LIST ILLUSTRATION Section 8 Pg 04 8 3 Enclosure 263612...
Page 50: ...PARTS LIST ILLUSTRATION Section 8 Pg 08 8 5 Inlet Valve Assembly 265400_r0...
Page 56: ...PARTS LIST ILLUSTRATION Section 8 Pg 14 8 8 Above Deck Hydraulic Drive 6100047ID_r0...
Page 60: ...BLANK PAGE...
Page 62: ...BLANK PAGE...
Page 63: ...BLANK PAGE...