background image

Highly

 

Rollkolbenverdichter 

Rotary Compressors

Spezifikation 

Installation Manual

RIES GmbH, Rudolf-Diesel-Str. 10, D 64569 Nauheim, GERMANY 

Phone: +49 6152 9741 0, Fax: +49 6152 9741 21, Email: 

[email protected]

, Website: www.ries-gmbh.de 

R 290

 

54,8

 cm3/rev

900 - 

66

00 min-1

WHP13300PSDPC8FQ

DC / BLDC

Summary of Contents for Highly WHP13300PSD

Page 1: ...ssors Spezifikation Installation Manual RIES GmbH Rudolf Diesel Str 10 D 64569 Nauheim GERMANY Phone 49 6152 9741 0 Fax 49 6152 9741 21 Email info ries gmbh de Website www ries gmbh de R 290 54 8 cm3 rev 900 6600 min 1 WHP13300PSDPC8FQ DC BLDC ...

Page 2: ...HE MODEL 3 THE PARAMETER OF MOTOR 4 CHARACTERISTICS 5 PARTS AND DRAWING LIST 5 15 HEAT PUMP Compressor CRITERIA 16 CHECK UPON DELIVERY 1 BASIS FOR CHECKING UPON DELIVERY 2 RULE FOR CHECKING UPON DELIVERY 17 26 DRAWINGS 0 27 30 ATTACHED PAGE 31 SPECIFICATION REVISION RECORD ...

Page 3: ...ower source input to inverter Rated voltage Rated frequency Phase 380V 50Hz 3ФOR 220V 50HZ 1Ф 2 3 Output 2630W 3600 min 1 2 4 Application Heat pump water heater 2 5 Performance Item Rated Condition Rotational speed 3600 min 1 Nominal Heating Capacity 13300W 5 Motor input 2860W 5 Current 11 5A 5 COP see 4 65 5 Test Conditions Evaporating temp 7 2 Condensing temp 54 4 Liquid temp entering expansion ...

Page 4: ...erant c h a r g e Below 1500g 2 11 Hermetic Terminal Conventinal Type 2 12 Space volume of inner case 1500cm 3 2 13 Compressor weight 18 9kg incl Oil 2 14 Motor Type Insulation class Direct current brushless motor E class 2 15 Compressor natural frequencies 19 9Hz 21 7Hz 24 5Hz 3Hz should be avoided or pass within ten seconds are compressor natural frequencies and they can be changed when connecti...

Page 5: ...tance Ld mH Sheet 2 3 5 Inductance Lq mH Sheet 2 3 6 Stator coil resistance 20 Ω 0 502 20 line to line 3 7 Voltage Constant Vrms krpm 43 10V krpm line to line 3 8 Torque Constant N m Ams 0 69 Torque Current 力矩 电流 3 9 Inertia Kg m2 0 000666 3 10 Flux Φa Wb 0 1702 φ Per Phase Peak 3 2 0 2 f E π φ 一相 peak 值 3 2 0 2 f E π 3 11 Magnet Material NdFeB Current 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 q 5 44 5 ...

Page 6: ...ING NO REMARKS Compressor 1 4CYCH0638 Dimensioned sketch Mounting Parts Rubber grommet Bolt Nut 3 4CYC00643 4CYC00700 M8 Electrical Parts Thermostat Terminal cover Gasket Nut Rubber washer Sleeve 1 1 1 1 1 1 4CYC01403 4CYC00988 4CYC01047 3CYC00004 4CYC00174 4CYC01042 4CYC01272 1 2 3 Lead routing Pressure guarantee Chart Pressure Guarantee Range Chart Notes for rotational speed change Performance c...

Page 7: ...ect current motor will demagnetize 3 Operating voltage range The compressor should be operated in the range of rated voltage 10 under standard condition and overload condition of rated frequency applied voltage to inverter It must be satisfied with item 5 6 7 4 Operating temperatures and pressures The operating temperatures and pressures of a compressor should be within the range shown in the tabl...

Page 8: ...25 Compressor suction side can handle the same maximum pressure as discharge side without damage when compressor is not running Compressor case bottom temp 99 or below and 6 higher than condensing temperature the time compressor case bottom temp 6 below the condensing temperature should be less than 5 minutes each time Requirement for high pressure ratio condition can be seen on page 28 Motor wind...

Page 9: ...tion 7 Pressure difference between suction and discharge 吸气 排气压力差 In all allowable rotational speed range the difference of pressure should be more than 0 39MPa 4kgf cm 2 But if there is no problem of noise when assembled in air conditioner it can also below this value the requirement can be seen on page 28 8 Discharge pipe temperature Discharge pipe temperature is measured at a distance 300mm fro...

Page 10: ...e minimum level Stopping time should be more than 3 minutes to make sure the suction pressure and discharge pressure is balance 12 Rate of rotational speed change The rate of compressor rotational speed acceleration should be less than 133min 1 s as the compressor speed is below 5400rpm while less than 60min 1 s as the compressor speed is higher than 5400rpm However when rotational speed is reduce...

Page 11: ...s washing fluid used at machining heat exchanger and tubes 15 Compressor vacuum operation Compressor should never be operated while under vacuum Otherwise internal arcing can cause damaging parts 16 The compressor should be operated for more than 20 seconds within 15 minutes after charging refrigerant into the system so proper lubrication results 17 Liquid refrigerant return limitations 有关液体制冷剂回流的...

Page 12: ...ving equipment such as automobiles trains ships etc 20 Installation The rotational axis of compressor should be kept vertical during operation But in actual application the axis incline must be within 5 at all directions during operation 21 Pipe vibration The displacement of the pipes which connect from the compressor to other parts of the refrigerate or systems should be less than 0 8mm 1 32 when...

Page 13: ...uld not apply partial force on projection parts such as pipe hermetic terminals foot during carrying and processing 2 The compressor should not be operated to form a vacuum and to absorb air The compressor only can run in one direction which according to lead routing wiring diagram Never reversion otherwise thecompressor will be in trouble 3 The compressor should not be left opened in the atmosphe...

Page 14: ...r of refrigerating systems e e Charge refrigerant to the compressor directly The refrigerant should always be charged in liquid state When the refrigerant is charged in gas state The percent component will possibly be changed 10 Temperatures within systems during stable compressor operation should not be less than 35 to prevent wax precipitation from the oil 11 The units of refrigerating system sh...

Page 15: ...sor to reach the temperature higher than 10 with heater if the ambient temperature is below 10 19 Set a thermistor on the case cover of compressor to prevent from accident of leakage of refrigerant The thermistor can stop the operation of compressor when compressor in abnormal temperature The lead wires of thermostat is enveloped with tube as same as that of the terminals to avoid directcontact wi...

Page 16: ...r 23 Be careful of avoiding oxide scale while soldering during assembly of refrigerating system for example flow or fulfill dry nitrogen 24 The quantity and kind of contamination the process materials in the cycle should be grasped and managed Carry on reliability test that input contamination a lot than anticipated contamination quantity 25 To avoid water and impurity into he refrigeration system...

Page 17: ... 31 27 The fuse or and breaker should be equipped in the main circuit 28 The thickness of the refrigerating system using tube the tube thickness as followed External diameter mm 6 35 6 35 11 0 11 0 13 0 13 0 15 0 15 0 19 0 Thickness 0 5 0 5 0 6 0 6 0 8 ...

Page 18: ...lar electrical appliances General requirements and GB 4706 17 Safety of household and similar electrical appliances Particular requirements for motor compressor 2 Rule for Checking upon Delivery If come across any quality problem please notify the company in written form within 30 days after the arrival of the cargo the company shall exchange exactly the number of the products otherwise they shall...

Page 19: ...17 31 ...

Page 20: ...18 31 ...

Page 21: ... 19 31 ...

Page 22: ...20 31 ...

Page 23: ...21 31 ...

Page 24: ...22 31 ...

Page 25: ...23 31 ...

Page 26: ...24 31 ...

Page 27: ...25 31 ...

Page 28: ...26 31 ...

Page 29: ...0 1 WHP13300PSDP Pd Pd PRESSURE MPa A 1000 2000 3000 4000 5000 6000 7000 8000 0 5 1 5 2 5 a b d c 1 Compressor running speed range Min 900min 1 Max 6600min 1 Rotational speed Pd limit 900 1 71 2000 3 13 5400 3 13 6600 2 34 27 31 ...

Page 30: ...mation of operating conditions the stage when pressure or temperature changing rapidly 28 31 Condition 1 Condition 2 Condition 3 Condit ion 4 Condit ion 5 Condit ion 6 Range of the conditions Ps Psmax 0 137 Ps 0 168MPa A Pressure ratio 8 Pressure ratio 1 5 Pressure difference 0 39 MPa The oil Temperatur SH 6 Operations requirement 1 Frequecy 70Hz 2 Ps 1 3MPa A 3 Pd Pdmax 1 Rotational speed N 6600r...

Page 31: ...29 31 ...

Page 32: ...gewünschten Drehzahl From starting to normal running Rotation speed Drehzahl 1 min 2 Niedrige Drehzahl und unregelmäßiger Betrieb Low speed un continuosly running Drehzahl Rotation speed 1 Os I I 2200 min 1 Min Drehzahl Speed 1 min 1 1 3 min 3 Abtauung Defrost mode unter Verwendung eines 4 Wege Ventiles b y using 4 way valve Drehzahl Rotation speed Max Drehzahl Max speed Max Drehzahl Speed 1 2400m...

Page 33: ...Specification Revision Record No Date Page in Spec Revision Reason Conclusion Date A B C D E F G H J K L M N P Q R S U V 31 31 ...

Reviews: