background image

www.valoya.com

+358 10 2350 300

Version 2018.1

Standards / Contact

14

Contact:

 Melkonkatu  26, 
 00210  Helsinki,
 Finland

 T

  +358 10 2350 300

 E

  [email protected]

 W

 www.valoya.com

Standards applied:

 

EUROPE

EN60598-1:

 Luminaires. General requirements and tests.

EN60598-2-1:

 Luminaires. Part 2: Particular requirements. Section one – Fixed general purpose luminaires.

EN62031:

 LED modules for general lighting. Safety specifications.

EN62493:

 Assessment of lighting equipment related to human exposure to electromagnetic fields.

EN55015:

 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment.

EN61547:

 Equipment for general lighting purposes. EMC immunity requirements.

EN61000-3-2:

 Electromagnetic compatibility - Limits - Limits for harmonic current emissions.

EN61000-3-3:

 Electromagnetic compatibility – Limits - Limits for Voltage Fluctuations and Flicker.

IEC EN 61000-4-2:

 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques - electrostatic discharge 

immunity test.

IEC EN 61000-4-3:

 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques - radiated, radio-frequency, 

electromagnetic field immunity test.

IEC EN 61000-4-4:

 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst 

immunity test.

IEC EN 61000-4-5:

 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test.

IEC EN 61000-4-6:

 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted 

disturbances, induced by radio-frequency fields.

IEC EN 61000-4-8:

 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic 

field immunity test.

IEC EN 61000-4-11:

 Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short 

interruptions and voltage variations immunity tests.

IEC 61347-2-13:

 Lamp controlgear. Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules.

IEC 61347-1 + A1:

 Lamp controlgear - Part 1: General and safety requirements.

IEC 62384 + A1:

 DC or AC supplied electronic control gear for LED modules. Performance requirements.

EN62471:

 Photobiological safety of lamps and lamp systems.

EN62560: 

Self-ballasted LED-lamps for general lighting services by voltage >50V - Safety specifications

EN62776:

 Double-capped LED lamps designed to retrofit linear fluorescent lamps - Safety specifications

NORTH AMERICA

UL1598:

 Luminare safety.

UL2108:

 Standard for Low Voltage Lighting Systems

UL8750:

 Light Emitting Diode (LED) equipment for use In lighting products.

CSA C22.2: #9.0: 

General Requirements for Luminaires

CSA C22.2: #250.0:

 Safety for Light emitting diode (LED) equipment for lighting applications.

CSA C22.2 No. 250.13:

 Light Emitting Diode (LED) equipment for use in lighting products..

 Distributor list can be found at:

www.valoya.com/contact

2018.1

Valoya® is a registered trademark of Valoya Oy in the European Community, the USA and certain other countries. 

Due to our continuous program of product development, data is subject to change without notice.

Summary of Contents for BL120

Page 1: ...Version 2018 1 www valoya com 358 10 2350 300 BL Series INSTALLATION GUIDE BL Series...

Page 2: ...Una instalaci n inadecuada puede provocar lesiones o da ar la l mpara ATENCION No seguir atentamente las instrucciones es peligroso y puede causar una descarga el ctrica Si la manguera flexible exteri...

Page 3: ...d elanslutning 3 Minsta avst nd till belyst f rem l 4 Endast f r inomhusbruk Arbetstemperatur 5 ndra eller l sg r inte n gon del av arma turen Valoya 1 2 3 4 5 SUOMI HUOMIO Valaisimen huolimaton asenn...

Page 4: ...29 Annex E No AC mains plug fitted No Physical Length mm in 1176 46 3 Width mm in 73 5 2 9 Height mm in 58 2 3 Weight kg lb 3 2 7 1 Cable length each end of luminaire mm in 300 11 8 Minimum distance f...

Page 5: ...ective compliant X Low Voltage Directive compliant X Eco design EuP directive compliant X Certified to UL CSA standards No Warranty 3 year limited warranty please refer to our terms conditions for mor...

Page 6: ...the carrier about the damage immediately Ask the carrier to write down a statement that the delivery was not delivered in good condition If the packaging shows no damage but the goods inside are defec...

Page 7: ...Version 2018 1 www valoya com 358 10 2350 300 Installation Instructions 7...

Page 8: ...require one 1 Wieland RST female mating connector to enable connection of a mains input cable and one 1 blank end cap to protect and seal the last connector of the chain These additional components ar...

Page 9: ...ion Installation Instructions IMPORTANT Maximum 16 luminaires to be connected to one 16A Type C MCB Higher rated MCB use is not permitted Use of an incorrectly rated MCB will cause a potential safety...

Page 10: ...ty on a 16A Type C MCB BX series BX90 BX120 BX180 6 BL series BL120 16 C series C65 C75 C90 6 R series R300 3 LightDNA 8 LightDNA 8 2 ICL INRUSH CURRENT LIMITER An ICL can help avoid nuisance MCB trip...

Page 11: ...to protect against surge peaks above 4KV e g due to a lightning strike we recommend the installation of transient voltage surge suppression Do not apply power without the Neutral connected Ensure the...

Page 12: ...and disconnect the luminaire unplug the Wieland input connector Connect the luminaire to a mains supply circuit known to be providing voltage If the problem remains then the luminaire may be damaged...

Page 13: ...e following information about the issue Product model information e g B200 NS1 Product serial number plus YF or XF code Quantity showing problems Detailed problem description Photograph or video showi...

Page 14: ...ectromagnetic compatibility EMC Part 4 6 Testing and measurement techniques Immunity to conducted disturbances induced by radio frequency fields IEC EN 61000 4 8 Electromagnetic compatibility EMC Part...

Reviews: