OWNER’S
INFORMATION
6
WARNING
DO NOT ATTEMPT TO TOUCH THE DATA CARD
WHILE THE FIREPLACE IS STILL HOT!
Let the
fi
replace cool
fi
rst before touching it.
!
Operating Your Fireplace for the First Time
When operating your new
fi
replace for the
fi
rst time,
some vapors may be released due to the burning of
curing compounds used in the manufacture of the
appliance. They may cause a slight odor and could
cause the
fl
ames to be the full height of the
fi
rebox, or
even slightly higher, for the
fi
rst few hours of operation.
It is also possible that these vapors could set o
ff
any
smoke detection alarms in the immediate vicinity.
These vapors are quite normal on new appliances. We
recommend opening a window to vent the room. After
a few hours use, the vapors will have disappeared and
the
fl
ames will be at their normal height.
Flame Supervision Device
For your safety, this appliance is
fi
tted with a
fl
ame
supervision device which will shut-o
ff
the gas supply
if, for any reason, the pilot
fl
ame goes out. This device
incorporates a
fi
xed probe, which senses the heat
from the pilot
fl
ame. If the probe is cool, the device
will prevent any gas
fl
ow unless manually lighting the
pilot. See full lighting instructions on page 8 of this
manual.
Introduction
Thank You ...
For purchasing a Valor by Miles Industries. Your new
radiant gas heater is a technical appliance that must
be installed by a quali
fi
ed dealer. Each Valor
fi
replace
is fully tested during the production process for your
safety and comfort.
Your unit has been professionally installed by:
Dealer Name: ________________________________
Phone Number :_______________________________
Should you encounter an operational problem, call
your dealer immediately.
Do not try to repair the unit as you may cause an
injury or damage the
fi
replace.
Locating Fireplace & Lighting Information Card
The Fireplace and Lighting Information card is located
under the
fi
rebox.
To access the card, remove the cast fret or the bottom
cover, grab the card and take it out to read it. There is
important information on both sides of the card.
739MN
FOR NATURAL GAS POUR LE GAZ NATUREL
750
24,000
6,500
3.2"
5.0"
4006176N/01
CIRCULATING FAN KIT 755CFK VENTILATEUR POUR CIRCULATION D'AIR 755CFK
#4003360-741, #4003293-742, #4003313-745, #4003426-765, #4004666 772
120V, 60Hz, LESS THAN 1A
120V, 60Hz, MOINS DE 1A
739N 10000
Fireplace
model
Serial
number
Performance of propane gas appliances may be
a
ff
ected by the quality of commercial gas sup-
plied in your area.
Your Fireplace’s Vent Safety Switch
This appliance is equipped with a vent safety switch
which, when activated, will turn o
ff
the burner and
pilot if the vent is blocked, disconnected, or if there is
excessive down draught.
If the safety switch is activated, wait for it to cool o
ff
before trying to light the appliance again. The safety
switch will cool o
ff
and reset itself automatically after
25 to 30 minutes.
In the event that the safety switch is activated
again, contact a quali
fi
ed service technician for
inspection.
Should the safety switch require replacement, only
use parts supplied by Miles Industries.