14
Installation Planning
Wood Framing
10-1/4”
[261 mm]
15”
[381 mm]
8”
[204 mm]
11-1/4”
[286 mm]
46-1/2” [1181 mm]
18-1/2”
[470 mm]
Combustible wall
fi
nish
zone
Non-combustible wall
fi
nish
zone
Combustible framing
material. See “
Appendix
D”
for details.
1/2” [13 mm] non-
combustible cement
board required in this
zone. May be covered
with max. 3/4” [19 mm]
combustible
fi
nish.
Combustible projec-
tions must otherwise
conform to allowable
clearances. See “Clear-
ances to Combustibles”
on page 13.
Max 1-1/4” [32 mm]
thickness combustible
wall
fi
nish allowed, if
within 4” of opening.
Combustible framing
material allowed.
Zero clearance stand-
o
ff
s (2 front, 2 rear).
HeatShift pipes (4)
5” Ø connect to ple-
num or termination
plates above, see
Appendix D
.
HeatShift plenum or duct plates framing required (top,
front, or sides). See “Appendix D” in this manual.
WARNING
Ensure weight of wall above is
NOT carried by the appliance.
46-3/4” [1187 mm]
From wall
2”
[51 mm]
Requires steel stud
under outlet open-
ing when using LDK4
plenum.
WARNING
There are restrictions for where drilling and
screwing may take place. See page 18 for details.