![Valor LT1 2500KN Installation Manual Download Page 57](http://html1.mh-extra.com/html/valor/lt1-2500kn/lt1-2500kn_installation-manual_3732639057.webp)
57
Installation
Checking Decorative Lighting
1. Slide both light shields back and out of their
retaining clips (left side
fi
rst, then right).
2. Remove both old bulbs by pulling them straight
out of the light shields.
3. Insert 2 new G6.35 35W halogen bulbs into the
ceramic receptacles in the light shields of the
wiring harness.
4. Test lighting using the remote control. (see page
66 for details)
5. Firmly slide the light shields down into the clips.
6. Restore power to the
fi
replace.
7. Reinstall window if it was removed (see page 31
for details).
This appliance comes with built-in decorative lighting
(see page 66 for use instructions). If a bulb is
burned out upon installation, it can be replaced. The
light bulbs are housed inside two shields, behind the
front cover and above the front window as shown.
Two G6.35 35W halogen bulbs are required for
replacement. Always replace both bulbs at once. Do
not use bulbs rated more than 50W.
WARNING
The lightbulbs in this appliance get
very hot when turned on, regardless of
whether the fireplace's main flame is on.
Ensure both the lights and fireplace have
a one hour cool down time after either
has been active to avoid serious injury.
Note:
The front cover and convection baffl
e are
shown removed for clarity in these instructions.
It is not necessary to remove the front cover or
convection baffl
e to carry out these steps.
Removing the window is not necessary, but
may make accessing the lights easier. See page
30 for details on how to remove the window.
Wear gloves when changing these bulbs. Most
bulb manufacturers recommend no skin contact
as oil from skin can shorten the bulbs’ lifespan.
WARNING
DO NOT access lamps from inside the
firebox!