background image

4005137-03

©2016, Miles Industries Ltd.

DV Gas Insert

739JN (NG) & 739JP (LPG)

Installation & Owner’s Manual

This manual contains instructions to install the

 

ENGINE ONLY. 

A front is

 also REQUIRED 

to 

complete this installation. A barrier screen is pro-
vided with the front. 

Refer to the manual sup-

plied with the front for installation.

— Do not store or use gasoline or other 

fl

 ammable vapors and liquids in the 

vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

 

Do not try to light any appliance.

 

Do not touch any electrical switch; do 
not use any phone in your building.

 

Leave the building immediately.

 

Immediately call your gas supplier from 
a neighbor’s phone. Follow the gas 
supplier’s instructions.

 

If you cannot reach your gas supplier, 
call the 

fi

 re department.

— Installation and service must be 

performed by a quali

fi

 ed installer, service 

agency or the gas supplier.

Ce guide est disponible en français sur demande.

This appliance is only for use with the type 
of gas indicated on the rating plate. This 
appliance is not convertible for use with 
other gases, unless a certi

fi

 ed kit is used.

This appliance is a domestic room-heating 
appliance. It must not be used for any other 
purposes such as drying clothes, etc.
This appliance is suitable for installation in a 
bedroom or bed sitting room.

This appliance may be installed in an 
after-market permanently located, 
manufactured (mobile) home where not 
prohibited by local codes.

HOT GLASS

 WILL 

CAUSE BURNS.

DO NOT TOUCH 

GLASS 

UNTIL COOLED.

NEVER 

ALLOW CHILDREN 

TO TOUCH GLASS.

DANGER

!

A barrier designed to reduce the risk of burns from the hot 
viewing glass is provided with this appliance and shall be 
installed for the protection of children and other at-risk 
individuals.

  

!

  WARNING

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly 
could result in serious injury, death, or 
property damage.

INSTALLER

Leave this manual 

with the appliance.

CONSUMER

Retain this manual 

for future reference.

Please read this manual 
BEFORE installing and 
operating this appliance.

L

EGEND

 G3

Summary of Contents for LEGEND G3 739JN

Page 1: ...ande This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used This appliance is a dom...

Page 2: ...Window 35 Synchronize Remote Control 36 Check Operation 36 Adjust Aeration if necessary 36 Install Front Trim and Barrier Screen 37 Install Handset Wall Holder 37 Wiring Diagram 38 Approved Venting Co...

Page 3: ...BE PLACED on or near the appliance This unit MUST be used with a vent system as described in this installation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assemb...

Page 4: ...e A physical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at r...

Page 5: ...r fireplace is fully tested during the production process for your safety and comfort Your unit has been professionally installed by Dealer Name ________________________________ Phone Number _________...

Page 6: ...AN CREME by ELCO WHITE OFF by RUTLAND TURTLE WAX Do not clean the glass while it is hot Always securely replace the window and the barrier screen before lighting If broken the glass pane may only be r...

Page 7: ...covered by the Valor warranty DANGER The window unit must be correctly installed fastened and sealed after servicing or serious bodily injury and or damage to the appliance may result To ensure a safe...

Page 8: ...ard The Lighting Operation and Rating information is located on a card under the burner To access the card remove the fret or access panel grab the card and take it out to read it There is important i...

Page 9: ...s off when the handle is perpendicular with the pipe ON parallel to pipe OFF perpendicular to pipe How to Ensure Your Fireplace Cannot Be Turned ON Inadvertently You can use one of the two following m...

Page 10: ...lame height NOTE Before using the remote control system for the first time the receiver and the handset must be synchronized See the section Remote Control Initial Set up on page 36 of this manual Set...

Page 11: ...hour Press small flame button to set the minute Press OFF or simply wait to return to MAN mode Double click large flame button Flame automatically goes to high fire HI will be displayed Manual Mode Ma...

Page 12: ...gramming SETTING THE DAYTIME TEMPERATURE SETTING THE NIGHTTIME SETBACK TEMPERA TURE Default Settings sun 23 C 74 F Default Settings moon OFF Press large flame button to increase Nighttime Setback Temp...

Page 13: ...ashes Press large flame button to set the hour Press large flame button to set the hour Press small flame button to set the minutes Press small flame button to set the minutes SETTING P1 ON TIME SETTI...

Page 14: ...ge in flame height for a period of 6 hours the appliance goes into pilot mode NOTE In TEMP or TIMER modes the flame height will vary according to room temperature The appliance will continue to work n...

Page 15: ...ew Front 4003313 765 Contemporary Surround 4003426 772MBF2 Matte Black Front 4004666 Optional Accessories Outer Surrounds Trims Frets See your dealer for your choice of Outer Surrounds Trims Frets Con...

Page 16: ...smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG VLGH ON OFF switch 1 in...

Page 17: ...Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 High Altitude Installations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4 500 feet 1 370...

Page 18: ...Barrier Screen required sold separately Fret optional sold separately 2 x 3 approved flex chimney liners running full length WARNING HOT HEARTH FLOOR The hearth or floor in front of the fireplace may...

Page 19: ...Outer Trim or Surround sold separately X Y Dimensions Cavity Check that masonry step does not interfere with install dimensions or vent pipe If mantel is combustible see section Clearances for allowab...

Page 20: ...Materials Combustible materials Material such as wood compressed paper plant fibers plastics or any material capable of igniting and burning whether flame proofed or not plastered or un plastered Non...

Page 21: ...rmination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vertical height 10 ft measured to bottom of termination Maximum horizontal run 4 ft measured center to c...

Page 22: ...ance 3 Check that you have everything 4 Clean cavity chimney ash dump and clean out 5 Install venting pipes 6 Attach conversion plate to existing fireplace 7 Install and test blower if used 8 Fit appl...

Page 23: ...le of 1 5 inch 38 mm or less through the lower sides or bottom of the firebox The access hole must be plugged with non combustible insulation after the gas supply line has been installed See Dimension...

Page 24: ...de in a safe place to avoid damage Install Fan if used If the 755CFK Circulating Fan Kit blower is to be installed we suggest that you do it now The fan cavity is accessible from the back of the fireb...

Page 25: ...the firebox 3 Apply RTV sealant to the collars on the vent slider and fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure with 4 tapping screw...

Page 26: ...t pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing of the gas supply piping...

Page 27: ...2 Install the rock support supplied with the ceramic rocks set re using the screws from 1 4 screws Install Liner Panels The following guidelines apply for all liners except the 739RGL Reflective Glas...

Page 28: ...panel against the firebox side The panel should be parallel to the edge of the burner plate Rotate the anchor back down to hold the panel 5 Tighten the side brick anchors on each side of the firebox...

Page 29: ...of the sheet metal support Note The rear log will appear slightly angled backward on the left side compared to the burner The space between the log and the burner is purposefully wider on the left th...

Page 30: ...to hide the sheet metal work Do NOT put any coal into the pilot area Notch in rear log Pin in front right log 4 Place the front right log on the burner and slide it to the left against the front left...

Page 31: ...erformance of the appliance 1 Install the Front Support Platform in the firebox carefully sliding it down between the burner and the front bottom edge for the firebox while avoiding scraping the side...

Page 32: ...g fire for 30 to 45 minutes This discoloration is unavoidable and will re form again Installation All Rocks installed Glass panel installed 6 Place the left twig across the second and third rocks from...

Page 33: ...er performance of the appliance Platform Place the platform into the firebox on top of the burner Logs 1 Identify the base log and place it in the cavity of the ceramic platform The protruding parts o...

Page 34: ...side cross log which has one pin at one end Insert the pin in the hole at the front left of the platform and rests the top part of the log into the notch of the rear log as indicated Pebbles Six pebbl...

Page 35: ...tly can leak carbon monoxide affect the performance of the fireplace damage components cause overheating resulting in dangerous conditions Damage caused by incorrect window installa tion is not covere...

Page 36: ...fireplace flame up and down using the remote control to confirm that the full range of inputs is achieved see the remote control operation instructions on pages 10 14 Adjust Aeration if necessary Lig...

Page 37: ...h plate IMPORTANT The location of the remote control handset is important to assure proper temperature regulation To obtain a constant temperature we recommend that the handset should be between 3 and...

Page 38: ...Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram Wiring Diagram QUALIFIED INSTALLER 38...

Page 39: ...o axial Adapter 46DVA GK TM 4CTA 4DCAT33 Aluminum Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmaster and...

Page 40: ...mage to the unit due to i Improper installation operational or environmental conditions ii Inadequate ventilation in the area or competition for air from other household equipment or appliances iii Ch...

Page 41: ...o Main Burner incl olive nuts 4000065 31 Burner Plate Access Panel 4001680 32 Module Gasket Rear 4000175 33 Module Gasket Right 4000174 34 Module Gasket Front 4000173 Spare Parts Code Description Part...

Page 42: ...4 LH Top Log 4003788 75 RH Top Log 4003789 76 RH Center Log 4003790 77 LH Front Log 4003792 78 RH Front Log 4003793 79 Loose Coals 4001843 80 Driftwood Kit 739DWK 81 Rear Log 4005615 82 Base Log 40056...

Page 43: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 42 45a 45b 14a NG LPG 13a 47 48 49 50 51 52 53 49a 72 73 74 75 76 77 78 79 44 55 56 57 58 59 60 61 54 62 63 70 7...

Page 44: ......

Page 45: ...tion provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model...

Page 46: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...

Reviews: