background image

Installation Planning

Existing Fireplace Preparation

A few points must be considered before inserting the 
739 into an existing 

fi

 replace cavity. Generally, no 

modi

fi

 cations are allowed to the existing 

fi

 replace that 

will compromise the integrity of the existing 

fi

 replace. 

Components that are bolted or screwed on such as 
dampers or baf

fl

 es may be removed to accommodate 

the installation of the 739 engine. 

Cutting away 

any sheet metal parts of the existing 

fi

 replace 

to accommodate the installation of the 739 is 
prohibited

. Check with local authorities if in doubt.

Clean Fireplace and Chimney

Have the chimney swept and the 

fi

 replace cavity 

including ash dumps and clean-outs cleaned before 
installing the 739 heater and vent liners. Any creosote 
or soot residue remaining in the 

fi

 replace cavity 

chimney or clean-out may cause odors or stains once 
the 739 insert is installed. Consult with chimney sweep 
for information on how best to clean.

Installer—READ THIS FIRST

1.  YOU NEED TO KNOW FROM THE 

HOMEOWNER   what accessories (surround, 
door, etc.) will be installed with this 

fi

 replace;

2.  Unpack the appliance.
3.  Check that you have everything.
4.  Clean cavity, chimney, ash dump, and clean-out.
5.  Install venting pipes.
6.  Attach conversion plate to existing 

fi

 replace.

7.  Install and test blower if used.
8.  Fit appliance into cavity.
9.  Connect and test gas supply.
10. Install liners and fuel bed.
11. Re

fi

 t window.

Existing Dampers

Factory-built, zero-clearance 

fi

 replaces will require the 

damper to be removed in order to install the vent liners. 
These dampers are usually bolted into place. Dampers 
in masonry 

fi

 replaces must be 

fi

 xed open and may 

remain in place.

Ash Retaining Curbs

Some 

fi

 replaces (particularly factory-built) have a 

raised curb at the front edge to retain ashes. Check the 
dimensions carefully to ensure the 739 engine will 

fi

 t 

behind any raised curb (some curbs may be removed 
separately from the refractory base).

12. Put batteries in receiver and remote control 

handset.

13. Set-up remote control.
14. Connect electrical wiring blower if used.
15. Verify operation and adjust aeration settings.
16. Install the remote control handset wall holder.

17. Instruct the homeowner on the operation and 

maintenance of the 

fi

 replace.

18. Install the surround trim, front 

and barrier screen

.

19. Install the fret if required.

Only quali

fi

 ed licensed or trained personnel 

should install this appliance.

QUALIFIED 
INSTALLER

22

Summary of Contents for LEGEND G3 739JN

Page 1: ...ande This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used This appliance is a dom...

Page 2: ...Window 35 Synchronize Remote Control 36 Check Operation 36 Adjust Aeration if necessary 36 Install Front Trim and Barrier Screen 37 Install Handset Wall Holder 37 Wiring Diagram 38 Approved Venting Co...

Page 3: ...BE PLACED on or near the appliance This unit MUST be used with a vent system as described in this installation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assemb...

Page 4: ...e A physical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at r...

Page 5: ...r fireplace is fully tested during the production process for your safety and comfort Your unit has been professionally installed by Dealer Name ________________________________ Phone Number _________...

Page 6: ...AN CREME by ELCO WHITE OFF by RUTLAND TURTLE WAX Do not clean the glass while it is hot Always securely replace the window and the barrier screen before lighting If broken the glass pane may only be r...

Page 7: ...covered by the Valor warranty DANGER The window unit must be correctly installed fastened and sealed after servicing or serious bodily injury and or damage to the appliance may result To ensure a safe...

Page 8: ...ard The Lighting Operation and Rating information is located on a card under the burner To access the card remove the fret or access panel grab the card and take it out to read it There is important i...

Page 9: ...s off when the handle is perpendicular with the pipe ON parallel to pipe OFF perpendicular to pipe How to Ensure Your Fireplace Cannot Be Turned ON Inadvertently You can use one of the two following m...

Page 10: ...lame height NOTE Before using the remote control system for the first time the receiver and the handset must be synchronized See the section Remote Control Initial Set up on page 36 of this manual Set...

Page 11: ...hour Press small flame button to set the minute Press OFF or simply wait to return to MAN mode Double click large flame button Flame automatically goes to high fire HI will be displayed Manual Mode Ma...

Page 12: ...gramming SETTING THE DAYTIME TEMPERATURE SETTING THE NIGHTTIME SETBACK TEMPERA TURE Default Settings sun 23 C 74 F Default Settings moon OFF Press large flame button to increase Nighttime Setback Temp...

Page 13: ...ashes Press large flame button to set the hour Press large flame button to set the hour Press small flame button to set the minutes Press small flame button to set the minutes SETTING P1 ON TIME SETTI...

Page 14: ...ge in flame height for a period of 6 hours the appliance goes into pilot mode NOTE In TEMP or TIMER modes the flame height will vary according to room temperature The appliance will continue to work n...

Page 15: ...ew Front 4003313 765 Contemporary Surround 4003426 772MBF2 Matte Black Front 4004666 Optional Accessories Outer Surrounds Trims Frets See your dealer for your choice of Outer Surrounds Trims Frets Con...

Page 16: ...smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG VLGH ON OFF switch 1 in...

Page 17: ...Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 High Altitude Installations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4 500 feet 1 370...

Page 18: ...Barrier Screen required sold separately Fret optional sold separately 2 x 3 approved flex chimney liners running full length WARNING HOT HEARTH FLOOR The hearth or floor in front of the fireplace may...

Page 19: ...Outer Trim or Surround sold separately X Y Dimensions Cavity Check that masonry step does not interfere with install dimensions or vent pipe If mantel is combustible see section Clearances for allowab...

Page 20: ...Materials Combustible materials Material such as wood compressed paper plant fibers plastics or any material capable of igniting and burning whether flame proofed or not plastered or un plastered Non...

Page 21: ...rmination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vertical height 10 ft measured to bottom of termination Maximum horizontal run 4 ft measured center to c...

Page 22: ...ance 3 Check that you have everything 4 Clean cavity chimney ash dump and clean out 5 Install venting pipes 6 Attach conversion plate to existing fireplace 7 Install and test blower if used 8 Fit appl...

Page 23: ...le of 1 5 inch 38 mm or less through the lower sides or bottom of the firebox The access hole must be plugged with non combustible insulation after the gas supply line has been installed See Dimension...

Page 24: ...de in a safe place to avoid damage Install Fan if used If the 755CFK Circulating Fan Kit blower is to be installed we suggest that you do it now The fan cavity is accessible from the back of the fireb...

Page 25: ...the firebox 3 Apply RTV sealant to the collars on the vent slider and fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure with 4 tapping screw...

Page 26: ...t pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing of the gas supply piping...

Page 27: ...2 Install the rock support supplied with the ceramic rocks set re using the screws from 1 4 screws Install Liner Panels The following guidelines apply for all liners except the 739RGL Reflective Glas...

Page 28: ...panel against the firebox side The panel should be parallel to the edge of the burner plate Rotate the anchor back down to hold the panel 5 Tighten the side brick anchors on each side of the firebox...

Page 29: ...of the sheet metal support Note The rear log will appear slightly angled backward on the left side compared to the burner The space between the log and the burner is purposefully wider on the left th...

Page 30: ...to hide the sheet metal work Do NOT put any coal into the pilot area Notch in rear log Pin in front right log 4 Place the front right log on the burner and slide it to the left against the front left...

Page 31: ...erformance of the appliance 1 Install the Front Support Platform in the firebox carefully sliding it down between the burner and the front bottom edge for the firebox while avoiding scraping the side...

Page 32: ...g fire for 30 to 45 minutes This discoloration is unavoidable and will re form again Installation All Rocks installed Glass panel installed 6 Place the left twig across the second and third rocks from...

Page 33: ...er performance of the appliance Platform Place the platform into the firebox on top of the burner Logs 1 Identify the base log and place it in the cavity of the ceramic platform The protruding parts o...

Page 34: ...side cross log which has one pin at one end Insert the pin in the hole at the front left of the platform and rests the top part of the log into the notch of the rear log as indicated Pebbles Six pebbl...

Page 35: ...tly can leak carbon monoxide affect the performance of the fireplace damage components cause overheating resulting in dangerous conditions Damage caused by incorrect window installa tion is not covere...

Page 36: ...fireplace flame up and down using the remote control to confirm that the full range of inputs is achieved see the remote control operation instructions on pages 10 14 Adjust Aeration if necessary Lig...

Page 37: ...h plate IMPORTANT The location of the remote control handset is important to assure proper temperature regulation To obtain a constant temperature we recommend that the handset should be between 3 and...

Page 38: ...Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram Wiring Diagram QUALIFIED INSTALLER 38...

Page 39: ...o axial Adapter 46DVA GK TM 4CTA 4DCAT33 Aluminum Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmaster and...

Page 40: ...mage to the unit due to i Improper installation operational or environmental conditions ii Inadequate ventilation in the area or competition for air from other household equipment or appliances iii Ch...

Page 41: ...o Main Burner incl olive nuts 4000065 31 Burner Plate Access Panel 4001680 32 Module Gasket Rear 4000175 33 Module Gasket Right 4000174 34 Module Gasket Front 4000173 Spare Parts Code Description Part...

Page 42: ...4 LH Top Log 4003788 75 RH Top Log 4003789 76 RH Center Log 4003790 77 LH Front Log 4003792 78 RH Front Log 4003793 79 Loose Coals 4001843 80 Driftwood Kit 739DWK 81 Rear Log 4005615 82 Base Log 40056...

Page 43: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 42 45a 45b 14a NG LPG 13a 47 48 49 50 51 52 53 49a 72 73 74 75 76 77 78 79 44 55 56 57 58 59 60 61 54 62 63 70 7...

Page 44: ......

Page 45: ...tion provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model...

Page 46: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...