background image

Warranty

1. Extended Warranty Coverage

For a period of up to ten (10) years, Miles Industries Ltd., (the “Company”) or its appointed distributor will at its option pay the 

initial purchaser for the repair of, or will exchange the following parts or components which are found to be defective in material or 

workmanship under normal conditions of use and service:

2. Two-Year Parts Warranty 

In addition, for two (2) years from the date of purchase, the Company, at its option, can repair or exchange all parts and components 

not listed above but that are found to have a 

bona fide

 defect in material or workmanship under normal conditions of use.

3. Conditions and Limitations

a)  The warranty registration card must be completed by the initial owner and returned to the Company within 90 days of purchase.

b)  Installation and maintenance must be performed by an authorized and trained dealer in accordance with the Company’s installation 

instructions.

c)  This warranty is void where installation of the unit does not conform to all applicable codes including national and local gas 

appliance installation codes and building and fire codes.

d)  The owner must comply with all operating instructions.

e)  The Company is not responsible for the labor costs to remove defective parts or re-install repaired or replacement parts.

f)  The first purchaser or user of the unit will be responsible for any shipping charges for replacement parts as well as travel time 

incurred by the dealer to perform the warranty work.

g)  This warranty applies to non-commercial use and service and is void if it is apparent that there is abuse, misuse, alteration, 

improper installation, accident or lack of maintenance to the unit.

h)  This warranty does not cover damage to the unit through:

i) 

Improper installation, operational or environmental conditions.

ii)  Inadequate ventilation in the area or competition for air from other household equipment or appliances.

iii)  Damage due to chemicals, dampness, condensation, or sulphur in the fuel supply lines which exceeds industry standards.

i)  This warranty does not cover glass, log breakage or damage to the unit while in transit.

j)  The Company does not allow anyone to extend, alter or modify this warranty and assumes no responsibility for direct, indirect or 

consequential damages caused by the unit. State or provincial laws where the first purchaser or user resides may provide specific 

rights to extend this warranty and, if so, the Company’s sole obligation under this warranty is to provide labor and/or materials in 

accordance with those laws.

4. Discharge of Liability

After two (2) years from the date of purchase, the Company may, at its option, fully discharge all obligations under this warranty by 

paying to the first purchaser/user the wholesale price of any defective parts.

5. No Other Warranty

All obligations to repair this unit are defined in this warranty. Some states or provinces may specifically mandate additional warranties 

on the part of manufacturers, but in the absence of such specific legislation, there is no other warranty or obligation expressed or 

implied.

Part or Component

Defect Covered

Maximum Warranty Period

Exterior steel casing

Corrosion

10 years

Glass

Loss of structural integrity

10 years

Cast iron parts

Corrosion

10 years

Firebox and heat exchanger

Corrosion (but not discoloration) causing 

loss of structural integrity

10 years

WARR

ANT

Y P

ROG

RAM

WARR

ANT

Y P

ROG

RAM

VA

LOR

CO M FO

R

T

VA

LOR

CO M FO

R

T

VA

LOR

CO M FO

R

T

If you have a problem with this unit, please contact your dealer or 

supplier immediately. Under no circumstances should you attempt 

to  service  the  unit  in  any  way  by  yourself.  The  warranties  in 

paragraphs 1 and 2 are provided only to the first purchaser/user of 

this unit, are not transferable and are subject to the conditions and 

limitations in paragraphs 3, 4 and 5. Please review the conditions 

and limitations carefully and strictly follow their requirements.

29

Summary of Contents for Legend 739ILN

Page 1: ...ble for installation in a bedroom or bed sitting room Manufactured by MILES INDUSTRIES LTD British Columbia Canada www valorfireplaces com Do not store or use gasoline or other flammable vapors and li...

Page 2: ...l your dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation manual is believed to be correct at the time o...

Page 3: ...tion 14 Ceramic Bricks Installation 15 Ceramic Logs Installation 15 Window Refitting 17 Remote Control Initial Set up 17 Operation Check Aeration Settings Adjustment 18 Remote Control Handset Wall Hol...

Page 4: ...ration Due to the high temperature the appliance should be LOCATED out of traffic areas and away from furniture and draperies Clothing or flammable material SHOULD NOT BE PLACED on or near the applian...

Page 5: ...h the current ANSI Z223 1 and or local codes having jurisdiction Heating value of gas in some areas is reduced to compensate for elevation consult your local gas utility to confirm For installations a...

Page 6: ...nstall into combustible construction This appliance is NOT APPROVED for installation with a zero clearance kit 739IL fireplace Chimney Terminal Cap Flashing 2 x 3 approved flex chimney liners running...

Page 7: ...tion Electrical inlet Optional Outer Trim or Surround sold separately X Y Dimensions Cavity Check that masonry step does not interfere with install dimensions or vent pipe If mantel is combustible see...

Page 8: ...red or un plastered Non combustible materials Material such as steel iron brick tile concrete or materials that bear the UL mark for zero 0 fire rating Sidewall Clearances Minimum distance from side o...

Page 9: ...for allowable vertical vent termination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vertical height 10 ft measured to bottom of termination Maximum horizontal...

Page 10: ...ce cavity Generally no modifications are allowed to the existing fireplace that will compromise the integrity of the existing fireplace Components that are bolted or screwed on such as dampers or baff...

Page 11: ...ill an access hole of 1 5 inch 38 mm or less through the lower sides or bottom of the firebox The access hole must be plugged with non combustible insulation after the gas supply line has been install...

Page 12: ...place to avoid damage electrical outlet fan cavity Fan installation If the 755CFK Circulating Fan Kit blower is to be installed we suggest that you do it now The fan cavity is accessible from the bac...

Page 13: ...the back of the firebox 3 Apply RTV sealant to the collars on the vent slider and fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure with 4 t...

Page 14: ...ting of that system at test pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing...

Page 15: ...pack the ceramic logs very carefully to avoid damaging the fragile material Install the logs as shown below Please note that the position of the Logs is critical to insure proper performance of the ap...

Page 16: ...end on the pin located on the rear log Rest its wider end on the the crook in the front left log at an angle of approximately 30 degrees from the center line of the fireplace to allow for the flame t...

Page 17: ...in the window seal Remote Control Initial Set up The receiver and the handset of the remote control sys tem must be initially synchronized before the first use 1 Insert alkaline batteries in the remot...

Page 18: ...ect the temperature sensor located in the remote handset Operation Check Aeration Settings Adjustment Operation Check Turn the fireplace flame up and down using the remote control to confirm that the...

Page 19: ...ion of the surface has the immediate effect of compromising the strength of the glass An emulsion type cleaner is recommended Use a soft damp cloth to apply the cleaner Dry the glass with a soft dry p...

Page 20: ...e appliance uses four 1 5 V AA alkaline batteries for its remote control receiver and one 9 V alkaline battery for its handset Batteries should last one to two seasons depending on usage Removing the...

Page 21: ...batteries you can turn off the appliance with the manual switch located on the right hand side of the valve If the 1265WSK Wall switch is installed and the remote control will not be used remove the b...

Page 22: ...rns automatically to maximum flame height 1 Make sure that the MAN knob on the valve is in ON position 2 Make sure that the switch on the valve is in the I position 3 Press and hold the OFF and large...

Page 23: ...sing either the or buttons Mode Sun Moon TEMP Daytime temperature setting Nighttime temperature setting TIMER Start time setting Stop time setting Flame Height The flame height can be adjusted in the...

Page 24: ...you get up P1 start time and to turn off when you leave for the day P1 stop time Then you can set your fireplace to turn on again at the end of the day P2 start time and to turn off when you go to be...

Page 25: ...kaline batteries NOTE With very low battery the valve shuts off the fire completely This does not happen when the power supply is interrupted CAUTION DO NOT USE a screwdriver or other metallic object...

Page 26: ...the oor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMATIC IGNITION g 1 Locate the pilot g 3 inside of rebox at Left H...

Page 27: ...Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram Wiring Diagram 27...

Page 28: ...r 46DVA ADF Co axial to Co linear Adapter 46DVA GCL TM 4CAA 556CLA Co linear to Co axial Adapter 46DVA GK TM 4CTA Aluminum Flexible Liner 3 diameter 2280 Series 3 ACFL NOTE 2 ply liner approved to CAN...

Page 29: ...or air from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not cove...

Page 30: ...t Mount 4000138 28 Pilot Gasket B 4000140 29 Burner Tray 4001676 30 Pipe Valve to Main Burner incl olive nuts 4000065 31 Burner Plate Access Panel 4001680 32 Module Gasket Rear 4000175 33 Module Gaske...

Page 31: ...NG LPG 18 20 25 21 22 23 24 19 49a 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 44 43 45 62 63 64 65 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 14a NG...

Page 32: ......

Page 33: ...39IL NG natural gas LPG propane Serial No Front Trim code description e g 743FVI Double Door FenderFire Purchase date mm dd yyyy Home Owner Name Address City Province State Postal Code Zip Phone Email...

Page 34: ...Product Postage needed Were you given all documentation and manuals for your product YES NO Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty...

Reviews: