INSTALLER GUIDE
Page 39
16.2 To remove the ignition microswitch.
See figure 38.
1.
Remove the bottom front cover and the
fire front casting.
2.
Disconnect the leads from the ignition
microswitch (The lower of the two
microswitches - See figure 38).
3.
Detach the microswitch and insulation
pad by removing two screws.
4.
Replace in the reverse order. Check that
the microswitch operates correctly by fully
closing it and observing that there are
sparks at the pilot electrode.
16.3 To remove the gas shut-off
microswitch.
(See figures 38 & 39).
1.
Remove the bottom front cover and the fire
front casting.
2.
Loosen the thermocouple nut to free the
microswitch leads and pull the leads clear of
the thermocouple interrupter block (See figure
39).
4.
Detach the bridging bracket, microswitch
assembly by removing two screws (See figure
38).
5.
Replace in the reverse order. When refitting
the leads to the interrupter block, make sure
that they are secured firmly to give a good
electrical contact.
16.4 To remove the fascia.
16.4.1 Dream/Masquerade/Excelsior & Petrus models.
1.
On Petrus models - remove the upper louvre assembly by lifting it upward and
forward.
2.
Remove the bottom front cover and the fire front
casting.
3.
Remove the two screws and washers securing
the bottom of the fascia to the sides of the
convection box (See figure 40).
4.
Carefully lift the fascia upward to clear the upper
retaining brackets on the convection box. Pull the
fascia clear and place carefully aside.
5.
Refit in the reverse order. Make sure that the
fascia is properly located over the upper retaining
brackets. See section 14 of this guide for detailed
fitting instructions.
© GDC Group Ltd. 2012
Figure 40. Fascia fixing.
Figure 39. Thermocouple interrupter
block
Figure 38. Microswitches