background image

15

 

VALOR HEATING

ERDINGTON, BIRMINGHAM B24 9QP

Because our policy is one of constant development and improvement, details may vary slightly from those given in this
publication.

© Valor Ltd

Summary of Contents for Heartbeat Oxysafe 426

Page 1: ...ons give sufficient details to enable this appliance to be installed and maintained satisfactorily However if further information is required our advice line will be pleased to help Ring 0345 626 341...

Page 2: ...9 Installing to hearth 9 Wall mounting 9 Gas supply connection 9 Coal window fitting 9 Full operating checks 10 Control setting checks 10 Reference pressure check 10 Final assembly checks 10 Outer ca...

Page 3: ...16kW 14 200Btu h 2 2 40kW 8 200Btu h 1 1 65kW 5 600Btu h Burner type Duplex Injectors Upper Bray Cat 99 Size 150B Lower Bray Cat 99 Size 240 Burner test pressure 17 46 0 75mbar cold 7 0 0 3in w g Pil...

Page 4: ...manufacturer s instructions Mortar must not be allowed to drop down and accumulate in the raked positions The fireplace opening must be within the following dimensions Width Max 423mm Min 305mm Heigh...

Page 5: ...n 150mm 150mm 12 5mm for every 25mm depth over 150mm 2 10 The minimum allowable distance to a corner wall or any other projection at either side of the appliance is 100mm 2 11 The space between the fi...

Page 6: ...top fitment containing the feet and feet shrouds indicates which items are for the left and right sides To ease identification at the assembly stage leave the parts in the polystyrene until you are re...

Page 7: ...rk temporarily refit the control knob to the tap spindle Depress the control knob and while keeping it depressed turn anticlockwise through approximately 60 to the 1 IGN position A spark should track...

Page 8: ...sure that the rectangular air relief openings are fully within the fireplace opening 3 4 3 Wall mounting Figure 12 The closure plate must be fitted and sealed to the fireplace opening using a suitable...

Page 9: ...gap between the screw head and the wall to hang the fire 4 2 3 Hang the fire on the upper screw making sure that the flue spigot engages through the closure plate 4 2 4 Mark the positions of the bott...

Page 10: ...ealing screw Relight the appliance Turn to the maximum output position and test around the sealing screw for gas soundness with a suitable leak detection fluid 6 FINAL ASSEMBLY CHECKS 6 1 Fit The Oute...

Page 11: ...the gas supply through the tap The valve is located in the body of the tap The valve should operate within 60 seconds of the pilot going out If the valve does not operate within this time limit do not...

Page 12: ...e knurled screws at the bottom corners Lift the window unit up to clear the top flange of the firebox and place carefully aside See fig 6 in installation section 8 1 3 Replace in the reverse order 8 2...

Page 13: ...ear 8 6 4 Remove the injector from the burner 8 6 5 Replace in the reverse order 8 7 To Disconnect The Gas Supply Pipe Access for gas supply disconnection may be easier if the floor plate is removed 8...

Page 14: ...C D E F G H J K Injector Upper Bray 99 Size 150b Injector Bray 99 Size 240 Gas Tap Copreci Spark Generator Spark Generator Pilot Unit Inlet Elbow Window Unit Control Knob Coal Dust Cage 1 1 1 1 1 1 1...

Page 15: ...15 VALOR HEATING ERDINGTON BIRMINGHAM B24 9QP Because our policy is one of constant development and improvement details may vary slightly from those given in this publication Valor Ltd...

Reviews: