Figure 7. Coal bed location

 Figure 6. Window surround fitting

3.

 

After cleaning, replace and

secure the window unit to the
firebox by turning the two screws

1

/

4

 turn clockwise with the

screwdriver.
Refit the window surround by
sliding the surround upwards to
locate its upper tabs in the slots
underneath the outer case hood.
Push the bottom of the surround
fully against the case cross panel.
Drop the surround down so that
the two screw heads at the back of
the surround locate in the
keyholes in the cross panel. See
figure 6.

Ceramic Coal

 

This product uses a fuel effect piece containing
Refractory Ceramic Fibres (RCF), which are man-
made vitreous silicate fibres. Excessive exposure to
this material may cause temporary irritation to eyes,
skin and respiratory tract. Consequently, it makes
sense to take care when handling this article to
ensure that the release of dust is kept to a minimum.   

 

Although light coatings of soot are usually burnt
off during normal use, the coal may benefit from
occasional cleaning.

 

Should any soot accumulation become excessive,
the fuel effect piece should be removed from the
fire for cleaning. Cleaning should be carried out in
a well ventilated area or in the open air by gently brushing with the pieces held away
from your face so that you avoid inhaling the dust. We do not recommend the use of a
normal domestic vacuum cleaner which may blow dust back into the air.

 

The coal can be lifted out of the fire box when the window surround and glass have
been removed as described on page 8.

 

When replacing the coal, make sure that it rests on the ledges at the sides of the firebox
and that its back face is touching the horizontal rib at the back of the firebox. See
figure7.

 

Replace the window and surround after cleaning.

Summary of Contents for Churchill LFE

Page 1: ...re for your gas fire Please read thoroughly before using and keep for future reference For Service Phone 0845 960 5040 Manufactured exclusively for British Gas Scottish Gas by Valor Heating Wood Lane...

Page 2: ...ighest Standards The manufacturer is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation The manufacturer is a...

Page 3: ...to provide our customers with many years trouble free service Your owner guide aims to improve your understanding and appreciation of your gas fire by providing simple and informative instructions to...

Page 4: ...a competent person In the United Kingdom installation must be in accordance with the latest edition of the Gas Safety installation use Regulations In the Republic of Ireland installation must be in ac...

Page 5: ...or any reason the flames go out Get advice about the suitability of any wall covering near your fire Soft wall coverings e g embossed vinyl etc which have a raised pattern are easily affected by heat...

Page 6: ...OWNER S GUIDE Page 6 APPLIANCE DIMENSIONS Figure 1 Dimensions...

Page 7: ...ice incorporates a probe which senses that the heat from the pilot flame is correct If this probe is cool the device will prevent any gas flow unless the control knob is held in at the ignition positi...

Page 8: ...e goes out while setting the control repeat the full lighting procedure If the fire repeatedly goes out have the fire serviced To turn the fire off Partially depress the control knob and turn clockwis...

Page 9: ...nd then dry Do not use abrasive cleaners as these will scratch the fire surface Window Glass Remove any stains on the window with a non abrasive cleaner such as a ceramic hob cleaner Do not use abrasi...

Page 10: ...t Consequently it makes sense to take care when handling this article to ensure that the release of dust is kept to a minimum Although light coatings of soot are usually burnt off during normal use th...

Page 11: ...gistered installer We recommend that all gas appliances and their flues wherever situated are checked annually Servicing If you require your fire to be serviced please contact British Gas or Scottish...

Page 12: ...available Please quote the part number when ordering Description Part No Ceramic coal 3001005 Window unit 3000627 Window surround 3001022 When fitting replacement parts follow the instructions contai...

Reviews: