OWNER’S GUIDE

Page 4

Graph 1 Combustible shelf clearances

SAFETY

IF YOU SMELL GAS

DON’T SMOKE
EXTINGUISH ALL NAKED FLAMES
DON’T TURN ELECTRICAL SWITCHES ON OR OFF
TURN OFF THE GAS SUPPLY AT THE METER
OPEN DOORS AND WINDOWS TO GET RID OF THE GAS
IMMEDIATELY CALL THE GAS EMERGENCY SERVICE – SEE YOUR
LOCAL TELEPHONE DIRECTORY

DO

 

Have the fire installed by a competent person. In the United Kingdom, installation
must be in accordance with the latest edition of the Gas Safety (installation & use)
Regulations. In the Republic of Ireland, installation must be in accordance with all
national and local regulations in force.

 

Have the chimney swept prior to installation if it was previously used for solid fuel.

 

Have the fire installed in accordance with the installation instructions

 

Provide a minimum clearance as shown in graph 1 above the top of the outer case to
any shelf made of wood or other combustible material.

Summary of Contents for Churchill LFE

Page 1: ...re for your gas fire Please read thoroughly before using and keep for future reference For Service Phone 0845 960 5040 Manufactured exclusively for British Gas Scottish Gas by Valor Heating Wood Lane...

Page 2: ...ighest Standards The manufacturer is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation The manufacturer is a...

Page 3: ...to provide our customers with many years trouble free service Your owner guide aims to improve your understanding and appreciation of your gas fire by providing simple and informative instructions to...

Page 4: ...a competent person In the United Kingdom installation must be in accordance with the latest edition of the Gas Safety installation use Regulations In the Republic of Ireland installation must be in ac...

Page 5: ...or any reason the flames go out Get advice about the suitability of any wall covering near your fire Soft wall coverings e g embossed vinyl etc which have a raised pattern are easily affected by heat...

Page 6: ...OWNER S GUIDE Page 6 APPLIANCE DIMENSIONS Figure 1 Dimensions...

Page 7: ...ice incorporates a probe which senses that the heat from the pilot flame is correct If this probe is cool the device will prevent any gas flow unless the control knob is held in at the ignition positi...

Page 8: ...e goes out while setting the control repeat the full lighting procedure If the fire repeatedly goes out have the fire serviced To turn the fire off Partially depress the control knob and turn clockwis...

Page 9: ...nd then dry Do not use abrasive cleaners as these will scratch the fire surface Window Glass Remove any stains on the window with a non abrasive cleaner such as a ceramic hob cleaner Do not use abrasi...

Page 10: ...t Consequently it makes sense to take care when handling this article to ensure that the release of dust is kept to a minimum Although light coatings of soot are usually burnt off during normal use th...

Page 11: ...gistered installer We recommend that all gas appliances and their flues wherever situated are checked annually Servicing If you require your fire to be serviced please contact British Gas or Scottish...

Page 12: ...available Please quote the part number when ordering Description Part No Ceramic coal 3001005 Window unit 3000627 Window surround 3001022 When fitting replacement parts follow the instructions contai...

Reviews: