The fireplace opening must be within the following dimensions:
(a)
The total height of the closure plate is 660mm and will accommodate a maximum
opening height of 650mm (This allows a 10mm overhang). Heights above
580mm (Inclusive of sealing tape) will leave the sealing tape and closure plate visible
above the appliance. A baffle is supplied with the fire which can be screwed to the
appliance to cover the sealing tape and closure plate. When using the baffle the
height of the sealing tape and closure plate can be extended to a maximum 630mm
before being visible (See section 8.1).
(b)
Any opening visible below the appliance may be closed in.
4.10.3
Wall mounting to conventional and pre-cast flues.
The minimum height figures shown in the table below reflect that an extra 50mm
(minimum) is required above the
finished floor level
when wall mounting (See figure
2). When the additional 50mm (minimum) is adhered to them the appliance can be
fitted without a hearth.
The wall opening must be within the following dimensions:
(*)
The total height of the closure plate is 660mm and will accommodate a maximum
opening height of 650mm (This allows a 10mm overhang). Heights above
580mm (Inclusive of sealing tape) will leave the sealing tape and closure plate visible
above the appliance. A baffle is supplied with the fire which can be screwed to the
appliance to cover the sealing tape and closure plate. When using the baffle the
height of the sealing tape and closure plate can be extended to a maximum 630mm
before being visible (See section 8.1).
Wall mounting to a conventional fireplace.
Any opening visible below the appliance may be closed in but the depth of the
catchment space within the wall opening must be as shown in figure 4.
Page 15
©
GDC Group Ltd. OCT 2016
INSTALLER GUIDE
Precast flue
Width
Height
Max.
440mm
Min.
305mm
Max.
610mm
(a)
Min.
544mm
(b)
Wall mounting
Width
Height
Max.
440mm
Min.
305mm
Max.
610mm
(*)
Min.
594mm