INSTALLER’S GUIDE
Page 14
Figure 9. Fitting the foam seal
Figure 8. Flue restrictor
Figure 7. Concealed connection seal piercing
5.
For concealed connection only:
Pierce a hole in the seal at the back of
the convection box. See figure 7. The
seal must envelop the pipe. If the hole
is larger than the pipe, seal it with
tape.
Do not pierce the seal unless the
supply pipe is to pass through it.
7.1
The Flue Restrictor
This appliance is supplied with a flue
restrictor for use where the flue
draught is excessive. The restrictor
must NOT be fitted where a precast flue or a
flue liner is used. For all other installations
the restrictor should be fitted. There may
however, be certain exceptional
circumstances where fitting the restrictor
causes the fire to fail the spillage test. In
such cases the restrictor will have to be
removed. After removal conduct the spillage
check again.
The restrictor is supplied
loose and is fixed with two
screws. See figure 8.
7.2
Fitting the Foam
seal
There is a length of self
adhesive foam seal
supplied with the fire. This
will need to be fitted to the
outer rear edges of the side
and top flanges of the
convection box. Be
careful not to stretch the
seal when measuring.
Ensure that there is no gap
between the foam seals
where they meet at the top
flange (See figure 9).