heard.
This sound is caused by an electromagnetic valve shutting off the gas supply
through the tap. The valve is located in the body of the tap. The valve should operate
within 60 seconds of the pilot going out.
If the valve does not operate within this
time limit do not allow the appliance to be used until the fault has been corrected.
This monitoring system must not be adjusted, bypassed or put out of
operation.
This monitoring system, or any of its parts, must only be exchanged using
Valor authorised parts.
17. FINAL REVIEW
1.
COMPLETE THE INFORMATION IN THE WARRANTY AND SERVICE SECTION
OF THE OWNER GUIDE (See last pages of the OWNER guide).
2.
If a gap is visible between the inner sides of the fascia and the ceramic side walls,
gently slide the walls forward.
3.
Visually inspect the appliance. Clean off any marks incurred during installation.
4.
Advise the customer how to operate the appliance. Explain to the customer that the
appliance has a flame failure & spillage monitoring system. Point out the explanation
of this system shown in the owner guide under “Operating the fire”. Advise that if the
fire goes out for any reason, wait at least three minutes before relighting. Stress that if
the monitoring system repeatedly shuts off the fire, the appliance should be switched
off and a specialist should be consulted.
5.
Advise the customer that they should read their owner guide before operating the
fire and always follow the advice in the section headed “Cleaning your fire”.
Stress that no extra ceramic fuel effect pieces must be added over and above
those supplied with the appliance and that any replacements must only be the
authorised spares. Warn that ignoring this advice could cause incomplete
clearance of the products of combustion with consequent health hazards. If you
have not done so already; attach or place the ceramic fuel effect guide inside
this guide.
6.
Advise the customer that the appliance will operate to its maximum potential if the
flue is primed during the first 20 – 30 minutes of use. To do this, simply turn the
control knob to its highest setting. This will also burn off any carbon deposits that may
have formed during previous use.
If using the appliance for long periods it is beneficial to change between settings. This
will also help to remove any carbon deposits that may form during use.
7.
Recommend that the appliance should be serviced by a competent person at least
annually.
8.
If the appliance is in premises in the United Kingdom occupied by a tenant, point
out that by law a landlord must have any gas appliance, flue and pipe work which is
situated in a tenant’s premises checked for safety at least every 12 months.
9.
Advise that the fire may give off a slight odour while new. This is quite normal and it
will disappear after a short period of use.
Page 37
©
Baxi Heating U.K. Limited 2011.
INSTALLER GUIDE