9. PREPARING APPLIANCE FOR INSTALLATION
Before continuing with the installation of the appliance complete the
information in the warranty and service section of the OWNER guide (See
last pages of the OWNER guide).
1.
Detach the burner unit from the
hotbox by removing two screws (See
figure 10). Lift the burner unit clear.
2.
Fit the two U- seals ‘A’ to the
bottom edges of the hotbox side
flanges (See figure 11).
3.
It is important that the grommet
‘K’ supplied in the loose parts
pack is fitted to the hole in the
rear of the hotbox.
For concealed connection only:
Pierce the grommet to allow the pipe to pass through it.
The grommet should envelop the pipe. If the hole is
larger than the pipe, seal it with tape.
Do not pierce
the grommet unless the supply pipe is to pass
through it
.
4.
This appliance is supplied with a flue restrictor for use
where the flue draught is excessive. Generally we
recommend the restrictor is NOT fitted where a precast
flue, metal flue box or a flue liner is used, however,
certain flues may work sufficiently to warrant its use.
There may however, be circumstances where fitting the
restrictor causes the fire to fail the spillage test. In such
cases the restrictor will have to be removed. After
removal conduct the spillage check again.
The restrictor is packed loose with the
appliance and is secured with the two
screws used for the down draft baffle.
Remove the two screws from the rear of
the appliance (See figure 12). DO NOT
remove the down draft baffle. Locate the
flue restrictor. Secure the down draft baffle
and restrictor plate in place using the two
screws removed previously (See figure 12).
©
Baxi Heating U.K. Limited 2011.
Page 24
Figure 12. Flue restrictor
Figure 11. U- Seals
Figure 10. Burner attachment points
INSTALLER GUIDE