9
Clearances based on diagram above in Inches [mm]
Mantel Projection A
1 [25]
4 [101]
8 [203]
14 [355]
Mantel Projection B*
34 [864]
36 [914]
38 [965] 40 [1016]
Combustible Mantel Clearances
* Measure taken from the underside of the mantel to
fi
nished hearth or surface that the unit is sitting on.
Finishing Materials
Combustible Materials:
Materials made of or surfaced
with wood, compressed paper, plant
fi
bers, plastics, or
other material that can ignite and burn, whether
fl
ame
proofed or not, or plastered or unplastered.
Non-Combustible Materials:
Material which will not
ignite and burn. Such materials are those consisting
entirely of steel, iron, brick, tile, concrete, slate, glass or
plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 °C.
Clearances
WARNING
Some materials or items, although safe,
may discolor, shrink, warp, crack, peel,
and so on because of the heat produced
by the fireplace. Avoid placing candles,
paintings, photos, and other items
sensitive to heat around the fireplace.
WARNING
HOT GLASS! The use of a screen in front
of the glass is highly recommended,
particularly in households with children
WARNING
HOT HEARTH/FLOOR! The hearth or floor
in front of the fireplace may become very
hot when the fireplace heats. Do not
use the hearth as a seat or shelf. Solid
wood flooring in front of the fireplace (if
allowed) may shrink during the heating
season due to heat.
A
B
Non-combustible hearth
With optional
Fan: depth
+3” (76 mm)
Do not put
furniture or
objects within
36” (914 mm)
of the front of
appliance