17
7.3.
# 817VAK Pipe Adapter Fitting
Fit the adapter #817VAK securely over the outer vent collars. See figure 15. Drill through the
adapter outer tube and the appliance outer collar for two #6 screws supplied.
Make sure that the
drill does not penetrate the inner tubes.
Secure with the screws.
7.4.
Top heat shield & Stand-off Fitting
See figures 16 & 17
•
Remove the screws at the top rear corner of the case sides.
•
Locate the heat shield over the vent pipe adapter.
•
Support the front of the shield on the two angle supports.
•
Secure the shield to the case sides by refitting the two screws at the top rear corners and by two screws from the pack
fitted near the front.
•
Bend the two top rear stand-offs and fit to the heat shield with three screws each – see figure 17.
7.5.
Support Angle Fitting
See figure 18
The distance from the wall angles to the front face of the heater case is adjustable between
3
/
8
” (10mm) and 1
3
/
16
” (30mm) to
allow for a range of wall finish material thicknesses (e.g. tile etc).
•
Fit the top angle support to the case top with three screws.
•
Fit the two side angle supports with two screws each. Fit the screws from inside the heater case.
Figure 18 Support angles
Figure 17 Top & rear
Stand-offs
Figure 16 Heat shield
Figure 15 #817VAK
Adapter
Summary of Contents for 535XAN
Page 15: ...15...