11
4.3.
Horizontal side termination
See figures 5 &6.
Can be used with either #551DVK standard vent kit
or another terminal cap and accessories.
Adapter #817VAK, one 90° vent elbow and pipe
lengths will be required.
(See venting options section of this manual).
All vent length dimensions and clearance limits are
as section 4.2.
The minimum floor location is shown in figure 6.
4.4.
Horizontal side or rear
snorkel termination
The dimensional requirements in sections
4.2 and 4.3 apply.
Adapter #817VAK, one 90° vent elbow and
pipe lengths will be required.
A thimble kit may also be necessary.
(See venting section of this manual).
4.5.
Corner location, horizontal
termination, 45° pipe bend
See figures 5 & 7.
Can be used with either #551DVK standard
vent kit or another terminal cap and
accessories.
Adapter #817VAK, one 90° vent elbow and
pipe lengths will be required. (See venting
section of this manual).
All vent length dimensions and clearance
limits are as section 4.2.
The minimum corner location is shown in fig. 7.
Figure 7
Figure 6
Summary of Contents for 535XAN