2.0  OPTIONS 

Heater engine unit # 530 X is available in either natural 
gas or LPG and comes equipped with either a simulated 
log or coal fuel bed in either fuel. The 530X engine unit is 
supplied standard with a rear vent D.V outlet and may be 
converted to a top outlet D.V with no extra parts required. 
The parts required to make the engine suitable for zero 
clearance are supplied with the various front trims (except 
549 front) 
 

2.1

 

Appliance styles 

 

President FS   

Free standing cast stove.(See fig. 1),  

President 536 

For recessed application, either zero 
clearance or insert . (See figure 2) 

Windsor Arch 
539/549

 

Arched Cast Iron Front for recessed 
application, either zero clearance (see 
fig 3) or insert (see fig 4 ). (549 
version is insert only )   

Bolero 541 

Contemporary cast iron front for 
recessed application, either zero 
clearance or insert(see fig 5) 

 

 
One of the above kits must be used with each 
installation. 

 
2.2  Additional optional features 

 
Circulating fan 

Having variable speed and 
temperature control, it is 
designed to boost the natural 
convection process through the 
appliance. It may be fitted 
before the fireplace is installed 
or retrofitted at a later date –  

Kit #555CFK

3336 CP 
Closure Plate 

33” high x 36” wide black 
closure plate with black 
aluminum extrusion edge. To 
cover openings for insert 
applications.

 

 
2.3  LP Gas  

 

 
LPG Conversion kit 

Burner & injector kit for 
conversion from natural gas to 
propane – 

Kit #554LPK

 
 
 
 
 
 
 
 
 
 
 

 

2.4  Venting options 
 
2.4.1  Direct vent installations (solid piping) 

A list of all approved venting accessories is shown on 
pages 48 and 49 of this manual.  
 

2.4.2  Direct Vent Co-Linear Installations for 
Free Standing or Recessed Installations 
(flexible piping) 

Converts the appliance outlet collars to accept two 3” dia. 
Flex liners for installation into existing solid fuel burning 
fireplaces and chimneys. Requires 

556 CLA

 adapter 

and 

923 GK

 termination kit along with either a 

980

 or 

991

 

termination cap.( 923GCL may be used in lieu of 556 
CLA adapter) 
 

 

 

2.4.3 B-vent installations – For President 
Free Standing only 

Kit #552BVX 

converts this appliance from a direct vent 

fireplace heater to a gravity vent fireplace heater for use 
with a 4” “B” type vent. A full installation and operating 
manual is supplied with the kit.  

   

Summary of Contents for 530XAN

Page 1: ...ted by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used This appl...

Page 2: ...emoval 9 4 Conversion to Top Outlet 9 5 Rear Outlet Preparation 9 6 DuraVent Co Linear 9 7 Valor 556 CLA Co Linear Adapter 9 8 Air Restrictor 10 INSTALLING HORIZONTAL TERMINATION 32 11 INSTALLING ROOF...

Page 3: ...t to burn paper or any other material in the appliance The venting terminal must not be recessed into a wall or siding The vent terminal on the outside wall must be kept free from obstructions No obje...

Page 4: ...floor level b In the event that the requirements of this subdivision can not be met at the time of completion of installation the owner shall have a period of thirty 30 days to comply with the above r...

Page 5: ...requirements shall be satisfied by the manufacturer 1 The referenced special venting system instructions shall be included with the appliance or equipment installation instructions and 2 The special v...

Page 6: ...ned to boost the natural convection process through the appliance It may be fitted before the fireplace is installed or retrofitted at a later date Kit 555CFK 3336 CP Closure Plate 33 high x 36 wide b...

Page 7: ...4 Above 7 up to 8 5 Above 8 up to 9 7 Above 9 up to10 8 Above 10 up to 12 9 More than 12 9 extra 1 for every 1 depth above 12 Mantle leg projection D Min clearance from appliance side E Up to 8 0 Mor...

Page 8: ...ion is intended for insert applications only and does not include the stand offs and insulation pads required for zero clearance applications Most recessed 530 insert applications will also require a...

Page 9: ...des 3 3 Wall Thickness The appliance vent is suitable for penetrating a combustible wall up to 14 36cm thick A non combustible wall can be any thickness up to the maximum horizontal run of vent pipe a...

Page 10: ...nstalled on a metal or wood panel extending the full width and depth of the appliance 4 2 Venting configurations 4 2 1 Flat on wall Requires Valor vent kit 551DVK or other pipe length with adapter 817...

Page 11: ...cm H Clearance to combustible materials all round vertical pipe run and at sides of horizontal pipe run 15 16in 3 3cm 4 2 4 Rear vent connection vertical vent rise with horizontal snorkel termination...

Page 12: ...w pipe lengths a vertical vent terminal and roof flashing will be required Various other ceiling or roof items may be necessary depending on the particular installation See venting options section of...

Page 13: ...pliance adapter two lengths of 3 dia flexible chimney liner co linear termination kit and flashing and either high wind vertical vent terminal cap or a low profile vertical termination cap See vent op...

Page 14: ...16in 3 3cm G Clearance to combustible materials all round vertical pipe run and at sides of horizontal pipe run 15 16in 3 3cm 4 2 12 Top vent connection vertical vent rise with horizontal side termina...

Page 15: ...e straight horizontal termination Figs 16 19 Can be used with either 551DVK standard vent kit or another terminal cap and accessories Adapter 817VAK one 90 elbow and pipe lengths will be required See...

Page 16: ...is necessary in an attic to avoid obstructions or allow useful space Adapter 817VAK two 45 vent elbows wall straps a vertical vent terminal roof flashing and pipe lengths will be required Various othe...

Page 17: ...erial if desirable see figs 24 25 Windsor Arch 539 Front comes with an integral back plate see fig 3 A non combustible hearth is not necessary in front of this appliance The appliance is approved to i...

Page 18: ...ithout the backplate does not come with zero clearance items and is intended for insert applications only Combustible wall finish may be used behind the cast iron plate up to the extent of the framed...

Page 19: ...extended by the use of any vent accessory pipes 5 5 2 Flat on wall with snorkel termination all fronts Fig 29 For use on horizontal vent installations where the outside ground level is too close to th...

Page 20: ...3cm H Clearance to combustible materials all round vertical pipe run and at sides of horizontal pipe run 15 16 3 3cm 5 5 4 Rear vent connection vertical vent rise with horizontal snorkel termination...

Page 21: ...t elbow pipe lengths a vertical vent terminal and roof flashing will be required Various other ceiling or roof items may be necessary depending on the particular installation See venting options secti...

Page 22: ...to combustible materials all round vertical pipe run and at sides of horizontal pipe run 15 16 3 3cm 5 5 10 Top vent connection vertical vent rise with horizontal side termination all fronts Figs 35...

Page 23: ...ths will be required See venting section of this manual All vertical dimensions and clearance limits are as section 5 5 9 5 5 13 Top vent connection vertical vent rise through the roof termination all...

Page 24: ...fset is necessary in an attic to avoid obstructions or allow useful space Adapter 817VAK four 45 vent elbows wall straps a vertical vent terminal roof flashing and pipe lengths will be required Variou...

Page 25: ...appliance Requires 556 CLA Co Axial to Co Linear appliance adapter or alternatively a 923 GCL two lengths of 3 dia flexible chimney liner co linear termination kit and flashing and either high wind ve...

Page 26: ...ion on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18 46 E Clearance to unventil...

Page 27: ...hread cutting screws 1 Deluxe remote control kit incl receiver and handset 551DVK Standard horizontal through the wall vent kit Alternative to Dura vent unit 1 Vent pipe terminal unit 2 Wall plates 2...

Page 28: ...mic Bricks Logs Coals from Firebox 9 2 Check ignition spark The pilot burner and electrode unit is at the left end of the burner Push in the lighting knob and turn counter clockwise through the IGN po...

Page 29: ...ollar and seal by unscrewing 8 screws See figure 44 4 To make sure that the collars are axially aligned fit the adapter 817VAK over the outer vent collar See figure 45 5 Position the inner collar and...

Page 30: ...lar on the connector is at the bottom See figure 47 4 Drill through the adapter outer tube and appliance outer collar for 6 screws See figure 46 Make sure that the drill does not penetrate the inner t...

Page 31: ...the restrictors remove the center screws from the rear ports and fit the restrictors using these screws To set the restrictors at maximum port opening slacken the bottom screws in the ports slide the...

Page 32: ...terline of the horizontal vent 10 3 Flat On Wall Installations With Valor 551DVK Terminal 1 Cut the vent terminal pipe unit to size Fig 51 Important The drain hole must be clearly outside the wall a M...

Page 33: ...with 4 screws provided See figure 54 5 FS installations Secure the appliance to the floor or wall if necessary 10 5 Installations except with Valor 551DVK Terminal Installing to wall Unless the wall i...

Page 34: ...p must be installed at the second floor and higher floors A ceiling support should be used below the flat ceiling To install the firestop support cut and frame a 10 254mm square hole centered on the s...

Page 35: ...y so please ensure that the wires are pointing up and slot in the board is inline with the tab on the wiring harness plug see fig 58 Connect wires as shown in Fig 58 Please note that the L connectors...

Page 36: ...ged 1 8 NPT tapping must be installed in the line The tapping must be accessible for test gauge connection and be immediately upstream of the gas supply connection to the appliance 7 Pressure test the...

Page 37: ...el effects and window installed See the Final checks section in this manual for adjustment details The shutter setting is very critical A change of 1 64 can make a substantial difference to the perfor...

Page 38: ...te the right middle log on the pin in the right hand side of the base log See fig 67 5 Locate the left side log on the ceramic pin on the left hand side of the base log Rest the narrow nose of this lo...

Page 39: ...uld be near the middle front of the firebox See figure 70 3 Place the right front coal behind the metal lip at the front of the firebox Its left side should rest over the projection on the left front...

Page 40: ...e the appliance and all other controls appliance rocker switch wall switch remote hand unit See owner s lighting instructions further on in this manual for full details 2 Aeration adjustment As descri...

Page 41: ...combustible material see fig 78 2 Install Top Air Deflector using 2 screws supplied see fig 79 3 Bolt left and right side castings in place using the bolts and washers supplied see fig 82 4 Hang the...

Page 42: ...Warning Failure to install the standoff spacers may result in a fire hazard Remove the two screws near each of the rear top corners of the appliance and the two screws near the rear top of each side B...

Page 43: ...e appliance back panel with two 3 8 thread cutting pointed end screws see figure 91 Fit the front plinth under the appliance front with two thread forming screws See figure 89 5 Install Top Insulation...

Page 44: ...baffle using the 2 screws provided as shown in fig 94 2 Mount Stand off Spacers The stand off spacers are supplied flat and are left and right handed Remove the two screws near each of the rear top co...

Page 45: ...ces with the cast iron arch Note The weight of the Cast Iron Surround must not be carried by the connection to the heater it must sit on a hearth or be securely screwed to the wall 6 Hang the Inner Ca...

Page 46: ...r flame level For instance you want to watch flames burn at their highest level and you don t mind if the room is too hot Here s what you do a Press either of the large up or down buttons b The word m...

Page 47: ...front unit Lift the front by holding the decorative grille Don t lift by holding the top See figure 101 Windsor Arch Pull away the ashguard at the bottom and unhook the Inner Cast Arch as shown in Fi...

Page 48: ...ecommend annually 19 5 Servicing All appliances use four 1 5V AA batteries for remote control receivers and the handset uses a 9V battery Batteries are accessible by opening the bottom access panel an...

Page 49: ...P Read the safety information above 2 Set the thermostat as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed...

Page 50: ...ise 982 4DT ST14 TERMINATION CAPS SNORKEL 36 Rise 981 4DT ST36 UNIVERSAL ADAPTER 3 FLEX COUPLER 2150 CO LINEAR FLEX CONNECTOR 923F CO AXIAL TO CO LINEAR ADAPTER 923GCL 556CLA VENT ADAPTERS COUPLERS CO...

Page 51: ...OOF FLASHING 0 12 6 12 943 4DT AF6 SV4FA ROOF FLASHING 7 12 12 12 943S 4DT AF12 SV4B FLASHINGS FLAT ROOF FLASHING 943F SV4F WALL THIMBLE 942 4DT WT SV4RSM STORM COLLAR 953 4DT SC SV4AC DECORATIVE PLAT...

Page 52: ...allation and building codes 4 3 Owner must comply with all operating instructions 4 4 This warranty is only valid under normal non commercial conditions of use and service This warranty is void if the...

Reviews: