Valor 530XAN Installation And Owner'S Manual Download Page 52

 

 

52 of  50

 
 

22.     MILES INDUSTRIES LTD. 

WARRANTY FOR VALOR BRAND PRODUCTS 

If you have a problem with this unit, please contact your dealer or supplier immediately.  Under no circumstances should you attempt to service the unit in 
any way by yourself. The warranties in paragraphs 1 and 2 are provided only to the first purchaser/user of this unit, are not transferable and are subject to the 
conditions and limitations in paragraphs 3, 4 and 5.  Please review the conditions and limitations carefully and strictly follow their requirements. 

1.

 

Lifetime Limited Parts Warranty 

During the lifetime of the first purchaser/user, (subject to paragraph 6) Miles Industries Ltd. (the “Company”) or its appointed distributor will at its option 
pay for the repair of, or will exchange the following parts or components which are found to be defective in material or workmanship under normal 
conditions of use and service

Part or Component 

Defect Covered 

 

Exterior steel casing 

Corrosion 

 

Glass 

Loss of structural integrity 

 

Burners and connecting pipes 

Corrosion (but not discolouration) causing loss of structural integrity 

 

Cast iron parts 

Corrosion 

 

Fire box and heat exchanger 

Corrosion (but not discolouration) causing loss of structural integrity 

2.

 

Two-Year Parts Warranty 

For a period of two years from the date of purchase (subject to paragraph 6,) the Company, at its option, will repair or exchange all parts or components of 
this unit (other than those listed in paragraph 1) which are found to be defective in material or workmanship

3.

 

Travel Time / Shipping Not Covered By Warranty 

Travel time by a repairer to perform warranty work or replace a part and any shipping charges incurred in respect of an exchange or replacement of a part 
shall be paid for by the owner of the unit. 

4.

 

Conditions and Limitations 

4.1

 

The warranty enrolment card must be completed by the first purchaser/user and countersigned by the dealer or a licensed, competent service 

contractor and returned to the Company within 90 days of purchase.  Registration can also be completed online at www.valorfireplaces.com. 

4.2

 

Installation and maintenance must be performed by a licensed Valor dealer or a licensed, competent service contractor.  Installation must comply with 

the enclosed installation instructions and all local and national gas appliance installation and building codes. 

4.3

 

Owner must comply with all operating instructions. 

4.4

 

This warranty is only valid under normal non-commercial conditions of use and service.  This warranty is void if there is evidence of misuse, abuse, 

alteration, improper installation, accident or lack of maintenance. 

4.5

 

This warranty is void where installation of the unit does not conform to all applicable codes including national and local gas appliance installation 

codes and building and fire codes. 

4.6

 

This warranty does not cover damage to the unit by: 

 

Improper or inadequate installation, or operational or environmental conditions including improper chimney installation. 

 

Inadequate ventilation or competition for air in the home from household equipment or appliances. 

 

Damage caused by chemicals; dampness; condensation; or sulphur in the fuel supply lines which exceeds acceptable industry standards

4.7

 

This warranty does not extend to or cover glass or log breakage due to misuse, accident, mishandling or lack of maintenance; brass which is damaged 

by chemicals or down draft conditions; chipping of enamel or painted surfaces or damage to the unit while in transit. 

4.8

 

The Company does not authorize anyone, including its dealers, to extend or alter this warranty in any way and assumes no responsibility for direct, 

indirect or consequential damages caused by this unit.  The laws of the state or province in which the first purchaser/user lives may give the first 
purchaser/user specific rights which extend this warranty and in that event, the Company’s sole obligation under this warranty is to provide labour and/or 
materials in accordance with those laws. 

5.

 

Discharge of Liability 

After two years from the date of purchase, the Company may, at its option, fully discharge all obligations under this warranty by paying to the first 
purchaser/user the wholesale price of any defective part.

 

6.

 

No Obligation to Pay Labour Costs

 

The Company shall not be responsible for the cost of labour to remove any defective part nor to reinstall any replacement or repaired part.  Repair work will 
be done at the place where the unit is installed or in the repairer’s shop, at the repairer’s option. 

7.

 

No Other Warranty 

The entire obligation to repair this unit is set forth in this warranty.  Some States or Provinces may specifically mandate additional warranties on the part of 
manufacturers, but in the absence of any such specifically mandated legislation, there is no other warranty or obligation expressed or implied.

 

Summary of Contents for 530XAN

Page 1: ...ted by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used This appl...

Page 2: ...emoval 9 4 Conversion to Top Outlet 9 5 Rear Outlet Preparation 9 6 DuraVent Co Linear 9 7 Valor 556 CLA Co Linear Adapter 9 8 Air Restrictor 10 INSTALLING HORIZONTAL TERMINATION 32 11 INSTALLING ROOF...

Page 3: ...t to burn paper or any other material in the appliance The venting terminal must not be recessed into a wall or siding The vent terminal on the outside wall must be kept free from obstructions No obje...

Page 4: ...floor level b In the event that the requirements of this subdivision can not be met at the time of completion of installation the owner shall have a period of thirty 30 days to comply with the above r...

Page 5: ...requirements shall be satisfied by the manufacturer 1 The referenced special venting system instructions shall be included with the appliance or equipment installation instructions and 2 The special v...

Page 6: ...ned to boost the natural convection process through the appliance It may be fitted before the fireplace is installed or retrofitted at a later date Kit 555CFK 3336 CP Closure Plate 33 high x 36 wide b...

Page 7: ...4 Above 7 up to 8 5 Above 8 up to 9 7 Above 9 up to10 8 Above 10 up to 12 9 More than 12 9 extra 1 for every 1 depth above 12 Mantle leg projection D Min clearance from appliance side E Up to 8 0 Mor...

Page 8: ...ion is intended for insert applications only and does not include the stand offs and insulation pads required for zero clearance applications Most recessed 530 insert applications will also require a...

Page 9: ...des 3 3 Wall Thickness The appliance vent is suitable for penetrating a combustible wall up to 14 36cm thick A non combustible wall can be any thickness up to the maximum horizontal run of vent pipe a...

Page 10: ...nstalled on a metal or wood panel extending the full width and depth of the appliance 4 2 Venting configurations 4 2 1 Flat on wall Requires Valor vent kit 551DVK or other pipe length with adapter 817...

Page 11: ...cm H Clearance to combustible materials all round vertical pipe run and at sides of horizontal pipe run 15 16in 3 3cm 4 2 4 Rear vent connection vertical vent rise with horizontal snorkel termination...

Page 12: ...w pipe lengths a vertical vent terminal and roof flashing will be required Various other ceiling or roof items may be necessary depending on the particular installation See venting options section of...

Page 13: ...pliance adapter two lengths of 3 dia flexible chimney liner co linear termination kit and flashing and either high wind vertical vent terminal cap or a low profile vertical termination cap See vent op...

Page 14: ...16in 3 3cm G Clearance to combustible materials all round vertical pipe run and at sides of horizontal pipe run 15 16in 3 3cm 4 2 12 Top vent connection vertical vent rise with horizontal side termina...

Page 15: ...e straight horizontal termination Figs 16 19 Can be used with either 551DVK standard vent kit or another terminal cap and accessories Adapter 817VAK one 90 elbow and pipe lengths will be required See...

Page 16: ...is necessary in an attic to avoid obstructions or allow useful space Adapter 817VAK two 45 vent elbows wall straps a vertical vent terminal roof flashing and pipe lengths will be required Various othe...

Page 17: ...erial if desirable see figs 24 25 Windsor Arch 539 Front comes with an integral back plate see fig 3 A non combustible hearth is not necessary in front of this appliance The appliance is approved to i...

Page 18: ...ithout the backplate does not come with zero clearance items and is intended for insert applications only Combustible wall finish may be used behind the cast iron plate up to the extent of the framed...

Page 19: ...extended by the use of any vent accessory pipes 5 5 2 Flat on wall with snorkel termination all fronts Fig 29 For use on horizontal vent installations where the outside ground level is too close to th...

Page 20: ...3cm H Clearance to combustible materials all round vertical pipe run and at sides of horizontal pipe run 15 16 3 3cm 5 5 4 Rear vent connection vertical vent rise with horizontal snorkel termination...

Page 21: ...t elbow pipe lengths a vertical vent terminal and roof flashing will be required Various other ceiling or roof items may be necessary depending on the particular installation See venting options secti...

Page 22: ...to combustible materials all round vertical pipe run and at sides of horizontal pipe run 15 16 3 3cm 5 5 10 Top vent connection vertical vent rise with horizontal side termination all fronts Figs 35...

Page 23: ...ths will be required See venting section of this manual All vertical dimensions and clearance limits are as section 5 5 9 5 5 13 Top vent connection vertical vent rise through the roof termination all...

Page 24: ...fset is necessary in an attic to avoid obstructions or allow useful space Adapter 817VAK four 45 vent elbows wall straps a vertical vent terminal roof flashing and pipe lengths will be required Variou...

Page 25: ...appliance Requires 556 CLA Co Axial to Co Linear appliance adapter or alternatively a 923 GCL two lengths of 3 dia flexible chimney liner co linear termination kit and flashing and either high wind ve...

Page 26: ...ion on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18 46 E Clearance to unventil...

Page 27: ...hread cutting screws 1 Deluxe remote control kit incl receiver and handset 551DVK Standard horizontal through the wall vent kit Alternative to Dura vent unit 1 Vent pipe terminal unit 2 Wall plates 2...

Page 28: ...mic Bricks Logs Coals from Firebox 9 2 Check ignition spark The pilot burner and electrode unit is at the left end of the burner Push in the lighting knob and turn counter clockwise through the IGN po...

Page 29: ...ollar and seal by unscrewing 8 screws See figure 44 4 To make sure that the collars are axially aligned fit the adapter 817VAK over the outer vent collar See figure 45 5 Position the inner collar and...

Page 30: ...lar on the connector is at the bottom See figure 47 4 Drill through the adapter outer tube and appliance outer collar for 6 screws See figure 46 Make sure that the drill does not penetrate the inner t...

Page 31: ...the restrictors remove the center screws from the rear ports and fit the restrictors using these screws To set the restrictors at maximum port opening slacken the bottom screws in the ports slide the...

Page 32: ...terline of the horizontal vent 10 3 Flat On Wall Installations With Valor 551DVK Terminal 1 Cut the vent terminal pipe unit to size Fig 51 Important The drain hole must be clearly outside the wall a M...

Page 33: ...with 4 screws provided See figure 54 5 FS installations Secure the appliance to the floor or wall if necessary 10 5 Installations except with Valor 551DVK Terminal Installing to wall Unless the wall i...

Page 34: ...p must be installed at the second floor and higher floors A ceiling support should be used below the flat ceiling To install the firestop support cut and frame a 10 254mm square hole centered on the s...

Page 35: ...y so please ensure that the wires are pointing up and slot in the board is inline with the tab on the wiring harness plug see fig 58 Connect wires as shown in Fig 58 Please note that the L connectors...

Page 36: ...ged 1 8 NPT tapping must be installed in the line The tapping must be accessible for test gauge connection and be immediately upstream of the gas supply connection to the appliance 7 Pressure test the...

Page 37: ...el effects and window installed See the Final checks section in this manual for adjustment details The shutter setting is very critical A change of 1 64 can make a substantial difference to the perfor...

Page 38: ...te the right middle log on the pin in the right hand side of the base log See fig 67 5 Locate the left side log on the ceramic pin on the left hand side of the base log Rest the narrow nose of this lo...

Page 39: ...uld be near the middle front of the firebox See figure 70 3 Place the right front coal behind the metal lip at the front of the firebox Its left side should rest over the projection on the left front...

Page 40: ...e the appliance and all other controls appliance rocker switch wall switch remote hand unit See owner s lighting instructions further on in this manual for full details 2 Aeration adjustment As descri...

Page 41: ...combustible material see fig 78 2 Install Top Air Deflector using 2 screws supplied see fig 79 3 Bolt left and right side castings in place using the bolts and washers supplied see fig 82 4 Hang the...

Page 42: ...Warning Failure to install the standoff spacers may result in a fire hazard Remove the two screws near each of the rear top corners of the appliance and the two screws near the rear top of each side B...

Page 43: ...e appliance back panel with two 3 8 thread cutting pointed end screws see figure 91 Fit the front plinth under the appliance front with two thread forming screws See figure 89 5 Install Top Insulation...

Page 44: ...baffle using the 2 screws provided as shown in fig 94 2 Mount Stand off Spacers The stand off spacers are supplied flat and are left and right handed Remove the two screws near each of the rear top co...

Page 45: ...ces with the cast iron arch Note The weight of the Cast Iron Surround must not be carried by the connection to the heater it must sit on a hearth or be securely screwed to the wall 6 Hang the Inner Ca...

Page 46: ...r flame level For instance you want to watch flames burn at their highest level and you don t mind if the room is too hot Here s what you do a Press either of the large up or down buttons b The word m...

Page 47: ...front unit Lift the front by holding the decorative grille Don t lift by holding the top See figure 101 Windsor Arch Pull away the ashguard at the bottom and unhook the Inner Cast Arch as shown in Fi...

Page 48: ...ecommend annually 19 5 Servicing All appliances use four 1 5V AA batteries for remote control receivers and the handset uses a 9V battery Batteries are accessible by opening the bottom access panel an...

Page 49: ...P Read the safety information above 2 Set the thermostat as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed...

Page 50: ...ise 982 4DT ST14 TERMINATION CAPS SNORKEL 36 Rise 981 4DT ST36 UNIVERSAL ADAPTER 3 FLEX COUPLER 2150 CO LINEAR FLEX CONNECTOR 923F CO AXIAL TO CO LINEAR ADAPTER 923GCL 556CLA VENT ADAPTERS COUPLERS CO...

Page 51: ...OOF FLASHING 0 12 6 12 943 4DT AF6 SV4FA ROOF FLASHING 7 12 12 12 943S 4DT AF12 SV4B FLASHINGS FLAT ROOF FLASHING 943F SV4F WALL THIMBLE 942 4DT WT SV4RSM STORM COLLAR 953 4DT SC SV4AC DECORATIVE PLAT...

Page 52: ...allation and building codes 4 3 Owner must comply with all operating instructions 4 4 This warranty is only valid under normal non commercial conditions of use and service This warranty is void if the...

Reviews: