4.2.14
Top vent connection,
corner location, vertical
rise, horizontal
termination, 45° pipe bend
(Figs 16 & 18)
Can be used with either #551DVK standard
vent kit or another terminal cap and
accessories.
Adapter #817VAK, one 90° elbow, one 45°
elbow and pipe lengths will be required.
(See venting section of this manual).
All vertical dimensions and clearance limits
are as section 4.2.11.
4.2.15
Top vent connection,
corner location, vertical
rise, straight horizontal
termination (Figs 16 & 19)
Can be used with either #551DVK standard
vent kit or another terminal cap and
accessories.
Adapter #817VAK, one 90° elbow and pipe
lengths will be required. (See venting
section of this manual).
All vertical dimensions and clearance limits
are as section 4.2.11.
.
4.2.16
Top vent connection, vertical vent rise,
through the roof termination (Fig. 20)
Adapter #817VAK, pipe lengths, a vertical vent terminal and
roof flashing will be required. Various other ceiling or roof
items may be necessary depending on the particular installation
(See venting options section of this manual).