7.3 Check reference pressure.
The appliance is pre-set to give the correct heat input at the inlet pressure shown in
section 3 of this manual. No adjustment is necessary.
1.
Ensure that the fire is turned OFF and detach the control knob from the spindle.
Remove the fascia. Remove the fascia and replace the control knob.
2.
Check the burner pressure by fitting a pressure gauge at the test point. The test
point is on the gas tap. Check the pressure with the appliance alight and set at
maximum output (Control position 5).
3.
After checking, turn off the appliance. Remove the pressure gauge and replace the
test point sealing screw. Relight the appliance. Turn to the maximum output position
and test around the sealing screw for gas soundness with a suitable leak detection
fluid. Turn the fire OFF and detach the control knob from the spindle.
4.
If all the above checks are satisfactory, continue with the installation. If not, check
the control and ignition circuitry and components as described in the servicing section
of this manual.
8. FASCIA FITTING
Before continuing with the installation of this appliance it is important that the
information contained on the back pages of the Owner guide is completed.
-
Place the fascia over the engine. Make sure
that the channel near the top of the rear of the
fascia locates fully into the wings of the engine
back panel (See figure 12).
-
The fire is supplied with a ‘special needs
control’ that users with impaired dexterity
may find easier to use.
Ask the customer if
they would prefer this to be fitted to the fire. Fit
the control knob firmly on to the control spindle.
-
Refit the two fascia retaining screws at the
rear of the fascia near the bottom.
Page 23
©
GDC Group Limited 2014.
INSTALLER GUIDE
Figure 12. Fascia top location