The fireplace opening must be within the following dimensions:
(a)
The total height of the closure plate is 660mm and will accommodate a maximum
opening height of 650mm (This allows a 10mm overhang). Heights above
620mm (Inclusive of sealing tape) will leave the sealing tape and closure plate visible
above the appliance.
(b)
Any opening visible below the appliance may be closed in.
4.10.3
Wall mounting to conventional or pre-cast flues.
The wall opening must be within the following dimensions: The minimum height
figures shown reflect that an extra 50mm is required above the
finished floor level
when wall mounting (See figure 2).
*
The total height of the closure plate is 660mm and will accommodate a maximum
opening height of 650mm (This allows a 10mm overhang). Heights above 620mm
(Inclusive of sealing tape) will leave the sealing tape and closure plate visible above
the appliance.
Wall mounting to a conventional fireplace.
Any opening visible below the appliance may be closed in but the depth of the
catchment space within the wall opening must be as shown in figure 4.
Wall mounting to a pre cast flue.
Important: If the base of the opening is above the finished floor level, the base must
be a maximum 350mm from the finished floor level. This will ensure that the air relief
hole in the closure plate is not covered or reduced.
Page 15
©
GDC Group Limited 2014.
INSTALLER GUIDE
Precast flue
Width
Height
Max.
440mm
Min.
305mm
Max.
610mm
(a)
Min.
525mm
(b)
Wall mounting
Width
Height
Max.
440mm
Min.
305mm
Max.
610mm*
Min.
575mm