39
Manifold
Test
Pressure
Valve Inlet
Pressure
Pressure Testing
Installation
Pressure Test Points
The minimum supply pressure is given in the section
Specifi cations
of this manual—page 20.
All piping and connections must be tested for leaks af-
ter installation or servicing. All leaks must be corrected
immediately.
When testing for leaks:
• Make sure that the appliance is turned off.
• Open the manual shut-off valve.
• Test for leaks by applying a liquid detergent or soap so-
lution to all joints. Bubbles forming indicate a gas leak.
Never use an open
fl
ame to check for leaks.
Correct any leak detected immediately.
The pressure test tapping locations are shown in the
fi
gure at right. An internal regulator within the valve con-
trols the burner manifold pressure. The correct pressure
range is shown in the table in section
Specifi cations
of
this manual on page 20. The pressure check should be
made with the burner alight and at its highest setting.
See
Lighting Instructions
section for full operating details
on page 17.
QUALIFIED
INSTALLER