20
X
Valve access side
Ratings
Model
N
P
Gas
Natural
Propane
Altitude (Ft.)*
0-4,500 feet*
Input Maximum (Btu/h)
30,000
26,000
Input Minimum (Btu/h)
18,000
18,500
Manifold Pressure (in
w.c.)
4.0”
10.0”
Minimum Supply
Pressure (in w.c.)
5”
11”
Maximum Supply
Pressure (in w.c.)
10”
14”
Main Burner Injector
Marking
850
260
Pilot Injector Marking
51
30
Min. Rate By-Pass
Screw
220
160
*High Altitude Installations
I
nput ratings are shown in BTU per hour and are
certi
fi
ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas utility
to con
fi
rm.
Speci
fi
cations
Approval & Codes
This appliance is certi
fi
ed to ANSI Z21.88-2014/
CSA 2.33-2014 American National Standard / CSA
Standard for
Vented Gas Fireplace Heaters
for use in
Canada and USA, and to CGA 2.17-91
High Altitude
Standard in Canada
. This appliance is for direct vent
installations.
This appliance complies with CSA P4.1-09
Testing
method for measuring annual fi replace effi ciencies
.
The installation must conform to local codes or, in the
absence of local codes, with the
National Fuel Gas
Code, ANSI Z223.1
or the
Natural Gas and Propane
Installation Code CAN/CGA-B149
. Only quali
fi
ed
licensed or trained personnel should install this
appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the
National Electrical Code, ANSI/NFPA
70
or the
Canadian Electrical Code, CSA C22.1
.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Supply Gas
Heater engine 1600IN is used with natural gas.
Heater engine 1600IP is used with propane gas.
The supply pressure must be between the limits shown
in the Ratings section above.
The supply connection is 3/8” NPT male and located
on the left hand side of the
fi
rebox. A shut-off valve (not
supplied) is required on the supply line to isolate the
unit during service. See
Gas Supply Installation
section
for details.
Conversion Kits
The 1600 L1 Two-Sided is supplied as natural gas or
propane gas and is
fi
eld convertible between fuels. See
instructions packaged with the conversion kit for further
information.
Electrical
The 1600 is designed to run on battery power and does
not require an electrical power source to operate as a
heater. However, it requires electrical power to operate
optional 1270RBK Remote Blower Kit.
QUALIFIED
INSTALLER