4
4. Plug the control module into the receiver.
5. Plug the 3-prong power cord’s molex connector into
the control module marked “POWER”.
1700 / 1800 J or K appliances:
Remove the plate to
the right of the opening to access fixing points for the
fan (4 screws).
2. Line up the slotted holes in the fan mounting plate
with the holes in the base of the liner box and fasten
using two screws provided.
Note:
Push fan as far back as possible before
tightening screws.
3. The thermal switch bracket is fixed to the underside
of the firebox floor from the top. Slightly loosen the
two screws holding it and slide the thermal switch
in between the bracket and the underside of the
firebox floor. Tighten the two screws to secure the
switch in position.
Slide thermal switch
between bracket
and underside of
firebox floor
Remove fan fixing access plate (4 screws)
1700 / 1800 J or K appliances:
secure fan through access hole
Bottom of fireplace transparent for clarity
Caution
DO NOT run wires over the top of the firebox.
Route the wire so they do not contact the firebox.